Home  > KEYSTONE ECTRONICS CORP(x)
View:
Danfoss offers a complete and flexible range of solenoid valves for use in refrigeration and A/C systems. EVR solenoid valves are direct or servo-operated solenoid valves for liquid, suction and hot gas lines. They are suitable for all refrigeration, freezing and air conditioning applications and are compatible with fluorinated refrigerants. Versions for high-pressure refrigerants are available by contacting Danfoss. The valves can be delivered as normally open or closed as well as with or without manual operation.
Danfoss 067N9407 Expansion Valve 11 Ton R22 5/8" x 7/8"
,
,



067N9407


067N9407

Item#:
067N9407
Manufacturer Item:
067N9407
Manufacturer:
DANFOSS LLC(HVAC/R)
  • Inlet size: 5/8"
  • Outlet size 5/8"
  • Connection Type: Solder
  • Max. Working Pressure [psig]: 260

    034L0029

  • Item#:
    034L0029
    Manufacturer Item:
    KVP15
    Manufacturer:
    DANFOSS LLC(HVAC/R)
    Danfoss SM185-4CA1 Scroll A/C Compressor 185K BTU R22 460/3,
    ,



    SM185-4CA1


    SM185-4CA1

    Item#:
    SM185-4CA1
    Manufacturer Item:
    SM185-4CAI
    Manufacturer:
    DANFOSS LLC(HVAC/R)
    Item#:
    HCZC0200UWF300N
    Item#:
    023Z8261
    Danfoss 018F4120 Solenoid Valve Coil 15 Watt 208/240 VAC
    • All HCFC and HFC refrigerants


      018F4120


      018F4120

    Item#:
    018F4120
    Manufacturer Item:
    BJ240CS
    Manufacturer:
    DANFOSS LLC(HVAC/R)
    Danfoss 013G8015 Nickel-Plated Brass Straight Thermostatic Radiator Valve Body, 1/2", FPT x MPT Union Tailpiece
      Valve bodies are designed to meet the demands of the residential, commercial and industrial sectors
    • Thermostatic radiator valves regulate the flow of hot water or low pressure steam through free-standing radiators, baseboards or convectors in hot water and 2-pipe steam systems
    • Valves are fitted with a packing gland assembly that is replaceable while the system is in operation
    • EPDM rubber valve disc provides a seal against the valve seat at differential pressures of up to 15 psig in hot water heating systems, while 15 psig for low pressure steam systems
    • Manual plastic cap supplied to protect the valve pusHPin and provide manual control of the valve during installation
    • Valves remain normally open with no operator mounted
    • Brass bonnet, spindle, nickel-plated brass tailpiece, union nut, EPDM disc, packing O-Ring, stainless steel spring,

      013G8015

    Item#:
    013G8015
    Manufacturer Item:
    013G8015
    Manufacturer:
    DANFOSS LLC(HVAC/R)
    Danfoss 117U5025 Start Capacitor
    • 280 MFD 125 VAC



      117U5025


      117U5025

    Item#:
    117U5025
    Manufacturer Item:
    117U5025
    Manufacturer:
    DANFOSS LLC(HVAC/R)
    Item#:
    117U4148
    Item#:
    117U6020
    Flow Rate
    • Atomizing noz.zles are available in a wide range of flow rates, all but eliminating the need for specially calibrated noz.zles. Between 1.00 GPH and 2.00 GPH, for example, seven different flow rates are available. Generally, with hot water and warm air heat, the smallest firing rate that will adequately heat the house on the coldest day is the proper size to use and the most economical. Short on-cycles result in low efficiency. Another guideline is to select the flow rate that provides a reasonable stack temperature regardless of the connected load. (According to the New England Fuel Institute, aim for a stack temperature of 400°F or lower on matched packaged units or 500°F or lower on conversion burners.) If the boiler or furnace is undersized for the load, it may be necessary to fire for the load and ignore the efficiency
    Spray Angle
    • Spray angles are available from 30° through 90° in most noz.zle sizes to meet the requirements of a wide variety of burner air patterns and combustion chambers. Usually it is desirable to fit the spray angle to the air pattern of the burner. In todays flame retention burner, it is possible to fire more than one spray angle with good results. Generally, round or square combustion chambers should be fired with 70° to 90° noz.zles. Long, narrow chambers usually require 30° to 60° spray angles.
    Burner Air Patterns
    • Burner air patterns are much like noz.zle spray patterns in that they fall into the same general classifications, either hollow or solid. As you would expect, a burner with a hollow air pattern generally requires a hollow cone fuel noz.zle. A burner with a solid air pattern will give highest efficiency with a solid cone noz.zle, but the flame will probably be longer


    .65-70AS

    Item#:
    .65-70AS
    Manufacturer Item:
    030F7514
    Manufacturer:
    DANFOSS LLC(HVAC/R)
    Danfoss 67L5957 Brass External Equalizer Type TR 6 Straightway Thermostatic Expansion Valve with Check Valve, 3/8" OD Solder, 5 Ton, R-41A
    • Valve have a balanced port design which reduces the influence from varying condensing pressures
    • Patented built-in check valve for air conditioning and heat pumps
    • Adjustable superheat setting
    • Anti-hunt charge
    • Robust stainless steel capillary tube and sensing bulb
    • Hermetic, laser welded, non-replaceable stainless steel power head
    • Factory static superheat setting 7.2 deg F
    • 24" equalizer capillary tube

    ,
    ,



    DAN067L5957


    DAN067L5957

    Item#:
    DAN067L5957
    Manufacturer Item:
    067L5957
    Manufacturer:
    DANFOSS LLC(HVAC/R)
    View: