Home  > RW BECKETT CORP(x)
|◀ 181 - 192 of 295 ▶|
View:
Williamsom-Thermoflo Parts BB-CHB/LB-140-S2 Oil Burner Beckett
    ,



    BB-CHB/LB-140-S2

Item#:
BB-CHB/LB-140-S2
Manufacturer Item:
WL4206C
Manufacturer:
RW BECKETT CORP
Beckett AFG70MDSS Air Tube Assembly 7" V1 Head,


Beckett Parts B5003

Item#:
B5003
Manufacturer Item:
B5003
Manufacturer:
RW BECKETT CORP
Boyertown Parts 540611B Oil Burner Boyertown


boyertown parts 540611b

Item#:
540611B
Manufacturer Item:
540611B
Manufacturer:
RW BECKETT CORP
Boyertown Parts 540609B Oil Burner Boyertown


boyertown parts 540609b

Item#:
540609B
Manufacturer Item:
540609B
Manufacturer:
RW BECKETT CORP




B2007

Item#:
B2007
Manufacturer Item:
B2007
Manufacturer:
RW BECKETT CORP
Beckett BPW201 Oil Burner



Beckett Parts BPW201

Item#:
BPW201
Manufacturer Item:
ADC
Manufacturer:
RW BECKETT CORP
R.W. Beckett 21173U Oil Burner Motor 1/5 HP 240 VAC 3450 RPM 1/2" Shaft,
,



21173U

Item#:
21173U
Manufacturer Item:
21173U
Manufacturer:
RW BECKETT CORP
Beckett 21805U Features
  • Permanent Split Capacitor: Lower amp draw, cooler operation, few failures
  • Ball Bearings: Longer lifeSpecifications
    • Electrical Input: 115V / 60Hz
    • Current Draw: 1.7 FLA
    • Speed: 3,450 rpm
    • Construction Type: PSC (Permanent Split Capacitor)
    • Bearing System: Ball bearing
    • Thermal Protector: Manual resetDimensions
      • Mounting frame: NEMA 48M
      • Lamination width: 3.7
      • Body length: 4.56
      • Body width: 3.93,

        ,



        Beckett Parts 21805U

Item#:
21805U
Manufacturer Item:
21805U
Manufacturer:
RW BECKETT CORP
Beckett 21444U Permanent Split Capacitor Burner Motor, 1/7 HP, 115 volt, 3450 RPM
  • Ball bearing system for longer life
  • Manual reset thermal overload protection
  • Permanent split capacitor construction for cooler operation and fewer failures
Sid Harvey Item #:A39-33: Replaces Part #:'s : 4H448,
,



beckett parts a39-33

Item#:
A39-33
Manufacturer Item:
21444U
Manufacturer:
RW BECKETT CORP
Beckett 7505A0000 Oil Burner Primary Control 15 Second
  • Water Resistant
  • Thermostat and boiler control compatible
  • Three status lights for system monitoring and diagnostics
  • Welded relay protection with redundant motor relays
  • 5-Year Warranty
  • Replaces Honeywell R8184G
  • Lockout time 15 Seconds
  • Pre-purge  0 seconds
  • Post-purge  0 seconds
  • Contractor Tool 52082U,
    ,




    beckett parts 7505a0000

  • Item#:
    7505A0000
    Manufacturer Item:
    7505A0000
    Manufacturer:
    RW BECKETT CORP
    Beckett 7505P1515 Oil Burner Primary Control 15 Second Lockout Timing
    The Beckett GeniSys advanced burner control is a 120 VAC primary safety control for residential and light commercial oil burners used in boiler, furnace and water heater applications. The GeniSys is used with a suitable cad cell flame sensor to control the oil burner motor, igniter and optional solenoid valve. It has 24 VAC thermostat terminals (if applicable) compatible with both mechanical and many power stealing thermostats.
    • Thermostat and boiler control compatible
    • Customizable pretime and post time
    • Three status lights for system monitoring and diagnostics
    • Welded relay protection with redundant motor relays
    • Limited reset and limited recycle
    • Sleek, modern design
    • Cad cell resistance indicator
    • Technician pump prime mode
    • Two communication ports for adding alarm contacts, programming display and future wireless communications
    • Output - 120 VAC motor, igniter, solenoid valve, 0.1 amp thermostat anticipator current
    • 5 years warranty
    Sid Harvey Item #:7505A0000: Replaces Part #:'s : R7284U1004,
    ,



    beckett parts 7505p1515

    Item#:
    7505P1515
    Manufacturer Item:
    7505P1515U
    Manufacturer:
    RW BECKETT CORP
    Beckett 7505P152M Oil Burner Primary Control 15 Second Lockout Timing
    The Beckett GeniSys advanced burner control is a 120 VAC primary safety control for residential and light commercial oil burners used in boiler, furnace and water heater applications. The GeniSys is used with a suitable cad cell flame sensor to control the oil burner motor, igniter and optional solenoid valve. It has 24 VAC thermostat terminals (if applicable) compatible with both mechanical and many power stealing thermostats.
    • Thermostat and boiler control compatible
    • Customizable pretime and post time
    • Three status lights for system monitoring and diagnostics
    • Welded relay protection with redundant motor relays
    • Limited reset and limited recycle
    • Sleek, modern design
    • Cad cell resistance indicator
    • Technician pump prime mode
    • Two communication ports for adding alarm contacts, programming display and future wireless communications
    • Output - 120 VAC motor, igniter, solenoid valve, 0.1 amp thermostat anticipator current
    • 5 years warranty
    Sid Harvey Item #:7505A0000: Replaces Part #:'s : R7284U1004,
    ,



    beckett parts 7505p152m

    Item#:
    7505P152M
    Manufacturer Item:
    7505P152MU
    Manufacturer:
    RW BECKETT CORP