Home  > INNER-TITE CORPORATION(x)
View:
Item#:
034L0029
Danfoss offers a complete and flexible range of solenoid valves for use in refrigeration and A/C systems. EVR solenoid valves are direct or servo-operated solenoid valves for liquid, suction and hot gas lines. They are suitable for all refrigeration, freezing and air conditioning applications and are compatible with fluorinated refrigerants. Versions for high-pressure refrigerants are available by contacting Danfoss. The valves can be delivered as normally open or closed as well as with or without manual operation.
  • Expansion Valve 11 Ton
  • R22
  • 5/8" x 7/8"

    Danfoss 067N9407

  • Item#:
    067N9407
    Manufacturer Item:
    067N9407
    Manufacturer:
    DANFOSS LLC(HVAC/R)
    Item#:
    SM185-4CA1
    Item#:
    HCZC0200UWF300N
    Danfoss Liquid Line Filter Drier
      Applications:
    • 1/4" OD
    • Traditional refrigeration
    • Air conditioning units
    • R1233zd(E); R1234yf; R1234ze(E); R134a; R22/R407C; R23; R32; R404A; R407F; R407H; R410A; R444B; R448A; R449A; R450A; R452A; R454A; R454C; R463A; R507A; R515B; R516A
    • 1/4" Flare Access
    • Transport refrigeration


    023Z8261

    Item#:
    023Z8261
    Manufacturer Item:
    DCL-1.52/CAPSV
    Manufacturer:
    DANFOSS LLC(HVAC/R)
    Danfoss Solenoid Valve Coil
  • 17.5 Watt
  • 120 VAC
  • With Junction Box
  • Coils for 13.5 mm Armature
  • Up to +50 C / +120 F

    Danfoss 018F4120

  • Item#:
    018F4120
    Manufacturer Item:
    BJ240CS
    Manufacturer:
    DANFOSS LLC(HVAC/R)
    Danfoss 013G8015 Nickel-Plated Brass Straight Thermostatic Radiator Valve Body, 1/2", FPT x MPT Union Tailpiece
      Valve bodies are designed to meet the demands of the residential, commercial and industrial sectors
    • Thermostatic radiator valves regulate the flow of hot water or low pressure steam through free-standing radiators, baseboards or convectors in hot water and 2-pipe steam systems
    • Valves are fitted with a packing gland assembly that is replaceable while the system is in operation
    • EPDM rubber valve disc provides a seal against the valve seat at differential pressures of up to 15 psig in hot water heating systems, while 15 psig for low pressure steam systems
    • Manual plastic cap supplied to protect the valve pusHPin and provide manual control of the valve during installation
    • Valves remain normally open with no operator mounted
    • Brass bonnet, spindle, nickel-plated brass tailpiece, union nut, EPDM disc, packing O-Ring, stainless steel spring,

      013G8015

    Item#:
    013G8015
    Manufacturer Item:
    013G8015
    Manufacturer:
    DANFOSS LLC(HVAC/R)
    Danfoss 117U5025 Start Capacitor
      280 MFD 125 VAC

      Danfoss 117U5025

    Item#:
    117U5025
    Manufacturer Item:
    117U5025
    Manufacturer:
    DANFOSS LLC(HVAC/R)
    Danfoss 117U4148 Relay/Overload Combo

    117U4148

    Item#:
    117U4148
    Manufacturer Item:
    117U4148
    Manufacturer:
    DANFOSS LLC(HVAC/R)
    Danfoss 117U6020 Starting Current Relay

    117U6020

    Item#:
    117U6020
    Manufacturer Item:
    117U6020
    Manufacturer:
    DANFOSS LLC(HVAC/R)
    Flow Rate
    • Atomizing noz.zles are available in a wide range of flow rates, all but eliminating the need for specially calibrated noz.zles. Between 1.00 GPH and 2.00 GPH, for example, seven different flow rates are available. Generally, with hot water and warm air heat, the smallest firing rate that will adequately heat the house on the coldest day is the proper size to use and the most economical. Short on-cycles result in low efficiency. Another guideline is to select the flow rate that provides a reasonable stack temperature regardless of the connected load. (According to the New England Fuel Institute, aim for a stack temperature of 400°F or lower on matched packaged units or 500°F or lower on conversion burners.) If the boiler or furnace is undersized for the load, it may be necessary to fire for the load and ignore the efficiency
    Spray Angle
    • Spray angles are available from 30° through 90° in most noz.zle sizes to meet the requirements of a wide variety of burner air patterns and combustion chambers. Usually it is desirable to fit the spray angle to the air pattern of the burner. In todays flame retention burner, it is possible to fire more than one spray angle with good results. Generally, round or square combustion chambers should be fired with 70° to 90° noz.zles. Long, narrow chambers usually require 30° to 60° spray angles.
    Burner Air Patterns
    • Burner air patterns are much like noz.zle spray patterns in that they fall into the same general classifications, either hollow or solid. As you would expect, a burner with a hollow air pattern generally requires a hollow cone fuel noz.zle. A burner with a solid air pattern will give highest efficiency with a solid cone noz.zle, but the flame will probably be longer


    .65-70AS

    Item#:
    .65-70AS
    Manufacturer Item:
    030F7514
    Manufacturer:
    DANFOSS LLC(HVAC/R)
    Danfoss Brass External Equalizer Type TR6 Straightway Thermostatic Expansion Valve with Check Valve
  • 3/8" OD Solder
  • 4 Ton
  • R410A
  • Valve have a balanced port design which reduces the influence from varying condensing pressures
  • Patented built-in check valve for air conditioning and heat pumps
  • Adjustable superheat setting
  • Anti-hunt charge
  • Robust stainless steel capillary tube and sensing bulbs.
  • Hermetic, laser welded, non-replaceable stainless steel power head
  • Factory static superheat setting 7.2 deg F
  • 24" equalizer capillary tube

    DAN067L5956

  • Item#:
    DAN067L5956
    Manufacturer Item:
    067L5956
    Manufacturer:
    DANFOSS LLC(HVAC/R)
    View: