S2K Commerce - Products Dropdown
S2K Commerce - Shopping Cart
S2K Commerce - Order Entry
Bussmann 626-HASR30 Class RK5 Time-Delay Fuse, 30 amp, 600 VAC
- These plugs offer safe protection during momentary overload
- No adapter necessary
Item#:
E356-57
Manufacturer Item:
ECSR-30
Manufacturer:
COOPER BUSSMAN LLC
Bussmann 626-HASR20 Class RK5 Time-Delay Fuse, 20 amp, 600 VAC
- Offer safe protection during momentary overload
- No adapter necessary
Item#:
E356-55
Manufacturer Item:
ECSR-20
Manufacturer:
COOPER BUSSMAN LLC
Bussmann 7-CRNR20 Dual Element Class RK5 Current-Limiting Time-Delay Fuse, 20 amp, 250 VAC
- Provides time delay for temporary over-current conditions and motor running protection
- Eliminates unnecessary maintenance from harmless overloads
Item#:
E356-41
Manufacturer Item:
ECNR-20
Manufacturer:
COOPER BUSSMAN LLC
Bussmann 7-CRNR30 Class RK5 Dual Element Current-Limiting Time-Delay Fuse, 30 amp, 250 VAC
- Eliminates unnecessary maintenance from harmless overloads
Item#:
E356-42
Manufacturer Item:
ECNR-30
Manufacturer:
COOPER BUSSMAN LLC
Bussmann 7-CRNR15 Dual Element Class RK5 Current-Limiting Time-Delay Fuse, 15 amp, 250 VAC
- Provides time delay for temporary over-current conditions and motor running protection
- Eliminates unnecessary maintenance from harmless overloads
Item#:
E356-40
Manufacturer Item:
ECNR-15
Manufacturer:
COOPER BUSSMAN LLC
Recommended for AC power distribution system mains, feeders and branch circuits having inductive loads motors, transformers or non-inductive loads lighting, heating, typically allows them to be sized closer to the running ampacity of inductive loads to reduce cost and provide improved overcurrent protection, override normal equipment current surges to reduce unnecessary fuse openings.
- True dual-element construction allows sizing of 125% FLA for motor backup protection
- Superior overload and cycling capabilities
- Provides motor overload, ground fault and short-circuit protection
- Helps protect motors against burnout from overloads and also from single phasing on three phase systems
- Current limiting provides component short circuit protection
- Simplifies and improves blackout prevention
- Dual-element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance, short circuit and overload protection
- The overload element provides protection against low level over current of overloads and will hold an overload which is five times greater than the ampere rating of the fuse for a minimum of ten seconds
Item#:
E356-45
Manufacturer Item:
ECNR-60
Manufacturer:
COOPER BUSSMAN LLC
The time-delay characteristics of these fuses typically allows them to be sized closer to the running ampacity of inductive loads to reduce cost and provide improved overcurrent protection. These fuses will override normal equipment current surges to reduce unnecessary fuse openings. Have moderate current limitation.
- True dual-element construction allows sizing of 125% FLA for motor backup protection
- Superior overload and cycling capabilities
- Provides motor overload, ground fault and short-circuit protection
- Helps protect motors against burnout from overloads and also from single phasing on three phase systems
- Current limiting provides component short circuit protection
- Simplifies and improves blackout prevention
- Dual-element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance, short circuit and overload protection
- The overload element provides protection against low level over current of overloads and will hold an overload which is five times greater than the ampere rating of the fuse for a minimum of ten seconds
Item#:
E356-46
Manufacturer Item:
ECNR-70
Manufacturer:
COOPER BUSSMAN LLC
Recommended for AC power distribution system mains, feeders and branch circuits having inductive loads motors, transformers or non-inductive loads lighting, heating, typically allows them to be sized closer to the running ampacity of inductive loads to reduce cost and provide improved overcurrent protection, override normal equipment current surges to reduce unnecessary fuse openings.
- True dual-element construction allows sizing of 125% FLA for motor backup protection
- Superior overload and cycling capabilities
- Provides motor overload, ground fault and short-circuit protection
- Helps protect motors against burnout from overloads and also from single phasing on three phase systems
- Current limiting provides component short circuit protection
- Simplifies and improves blackout prevention
- Dual-element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance, short circuit and overload protection
- The overload element provides protection against low level over current of overloads and will hold an overload which is five times greater than the ampere rating of the fuse for a minimum of ten seconds
Item#:
E356-43
Manufacturer Item:
ECNR-40
Manufacturer:
COOPER BUSSMAN LLC
Diversitech 7-CRNR50 Dual Element Class RK5 Current-Limiting Time-Delay Fuse, 50 amp, 250 VAC
- Provides time delay for temporary over-current conditions and motor running protection
- Eliminates unnecessary maintenance from harmless overloads
Item#:
E356-44
Manufacturer Item:
ECNR-50
Manufacturer:
COOPER BUSSMAN LLC
Bussman SEC10 Time-Delay Fuse 10 AMP 600 VAC Edison
Item#:
SEC10
Manufacturer Item:
SEC 10
Manufacturer:
COOPER BUSSMAN LLC
Bussman SEC25 Time-Delay Fuse 25 AMP 600 VAC Edison
Item#:
SEC25
Manufacturer Item:
SEC 25
Manufacturer:
COOPER BUSSMAN LLC