APPLICATION VERSATILITY
Standard Upflow without field modification. Downflow applications require field-installed downflow kit, sold separately.
AHRI certifiable with all brands of A/C and heat pump systems.
ETL listed for R22 and 410A. ETL listed for R454B and R32 with Refrigerant Detection System (RDS).
A2L refrigerants require a Refrigerant Detection System (RDS) for compliance.
A1 (R410A and R22) products manufactured in 2025 or later will be labeled as For servicing existing equipment only.
FEATURES
Rifled copper tubing, enhanced aluminum fins.
Fully insulated cabinets with faced insulation. Split access doors in front of cabinet for easy service access.
Heavy duty plastic drain pans on most models, powder coated galvanized steel horizontal drain pans standard on all.
Schrader provided for pressure assurance testing.
Multi-stage leak testing at 500 psi pressure decay, mass spectrometer tested with Helium, then Nitrogen pressurized and factory sealed for maximum reliability.
Aspen CE30A3N-145L-135
Item#:
CE30A3N-175L-135
Manufacturer Item:
CE30A3N-175L-135
Manufacturer:
ASPEN MFG. LLC
FEATURES
Rifled copper tubing, enhanced aluminum fins.
Fully insulated cabinets with faced insulation.
Split access doors in front of cabinet for easy service access.
Refrigerant and plumbing connections:
Immersion tested at 500 psi, followed by nitrogen pressurization and factory sealing to ensure optimal system integrity and long-term reliability.
Schrader provided for pressure assurance testing with 3/8 ODS Stem mounted on end of Liquid Line.
Condensate Drains: 3/4 NPT
Liquid line: 3/8 ODS
Suction line: 3/4 ODS on 1-1/2-ton to 3-ton 7/8 on 3-1/2-ton to 5-ton
Refrigerant and plumbing connections:
Aspen CH36A3G-100L-000
Item#:
CH48A3G-100L-000
Manufacturer Item:
CH48A3G-000
Manufacturer:
ASPEN MFG. LLC
APPLICATION VERSATILITY
Standard Upflow without field modification. Downflow applications require field-installed downflow kit, sold separately.
AHRI certifiable with all brands of A/C and heat pump systems.
ETL listed for R22 and 410A. ETL listed for R454B and R32 with Refrigerant Detection System (RDS).
A2L refrigerants require a Refrigerant Detection System (RDS) for compliance.
A1 (R410A and R22) products manufactured in 2025 or later will be labeled as For servicing existing equipment only.
FEATURES
Rifled copper tubing, enhanced aluminum fins.
Fully insulated cabinets with faced insulation. Split access doors in front of cabinet for easy service access.
Heavy duty plastic drain pans on most models, powder coated galvanized steel horizontal drain pans standard on all.
Schrader provided for pressure assurance testing.
Multi-stage leak testing at 500 psi pressure decay, mass spectrometer tested with Helium, then Nitrogen pressurized and factory sealed for maximum reliability.
Aspen CE42A34-210L-135
Item#:
CE42A3N-210L-135
Manufacturer Item:
CE42A3N-210L-135
Manufacturer:
ASPEN MFG. LLC
APPLICATION VERSATILITY
Standard Upflow without field modification. Downflow applications require field-installed downflow kit, sold separately.
AHRI certifiable with all brands of A/C and heat pump systems.
ETL listed for R22 and 410A. ETL listed for R454B and R32 with Refrigerant Detection System (RDS).
A2L refrigerants require a Refrigerant Detection System (RDS) for compliance.
A1 (R410A and R22) products manufactured in 2025 or later will be labeled as For servicing existing equipment only.
FEATURES
Rifled copper tubing, enhanced aluminum fins.
Fully insulated cabinets with faced insulation. Split access doors in front of cabinet for easy service access.
Heavy duty plastic drain pans on most models, powder coated galvanized steel horizontal drain pans standard on all.
Schrader provided for pressure assurance testing.
Multi-stage leak testing at 500 psi pressure decay, mass spectrometer tested with Helium, then Nitrogen pressurized and factory sealed for maximum reliability.
Aspen CE48A34-210L-135
Item#:
CE48A3N-210L-135
Manufacturer Item:
CE48A3N-210L-135
Manufacturer:
ASPEN MFG. LLC
APPLICATION VERSATILITY
Standard Upflow without field modification. Downflow applications require field-installed downflow kit, sold separately.
AHRI certifiable with all brands of A/C and heat pump systems.
ETL listed for R22 and 410A. ETL listed for R454B and R32 with Refrigerant Detection System (RDS).
A2L refrigerants require a Refrigerant Detection System (RDS) for compliance.
A1 (R410A and R22) products manufactured in 2025 or later will be labeled as For servicing existing equipment only.
FEATURES
Rifled copper tubing, enhanced aluminum fins.
Fully insulated cabinets with faced insulation. Split access doors in front of cabinet for easy service access.
Heavy duty plastic drain pans on most models, powder coated galvanized steel horizontal drain pans standard on all.
Schrader provided for pressure assurance testing.
Multi-stage leak testing at 500 psi pressure decay, mass spectrometer tested with Helium, then Nitrogen pressurized and factory sealed for maximum reliability.
Aspen CE60A34-210L-135
Item#:
CE60A3N-210L-135
Manufacturer Item:
CE60A3N-210L-135
Manufacturer:
ASPEN MFG. LLC
APPLICATION VERSATILITY
Standard Upflow without field modification. Downflow applications require field-installed downflow kit, sold separately.
AHRI certifiable with all brands of A/C and heat pump systems.
ETL listed for R22 and 410A. ETL listed for R454B and R32 with Refrigerant Detection System (RDS).
A2L refrigerants require a Refrigerant Detection System (RDS) for compliance.
A1 (R410A and R22) products manufactured in 2025 or later will be labeled as For servicing existing equipment only.
FEATURES
Rifled copper tubing, enhanced aluminum fins.
Fully insulated cabinets with faced insulation. Split access doors in front of cabinet for easy service access.
Heavy duty plastic drain pans on most models, powder coated galvanized steel horizontal drain pans standard on all.
Schrader provided for pressure assurance testing.
Multi-stage leak testing at 500 psi pressure decay, mass spectrometer tested with Helium, then Nitrogen pressurized and factory sealed for maximum reliability.
Aspen CC60A3J-245L-189
Item#:
CE24A34-145L-135
Manufacturer Item:
CE24A34-145L-135
Manufacturer:
ASPEN MFG. LLC
APPLICATION VERSATILITY
Standard Upflow without field modification. Downflow applications require field-installed downflow kit, sold separately.
AHRI certifiable with all brands of A/C and heat pump systems.
ETL listed for R22 and 410A. ETL listed for R454B and R32 with Refrigerant Detection System (RDS).
A2L refrigerants require a Refrigerant Detection System (RDS) for compliance.
A1 (R410A and R22) products manufactured in 2025 or later will be labeled as For servicing existing equipment only.
FEATURES
Rifled copper tubing, enhanced aluminum fins.
Fully insulated cabinets with faced insulation. Split access doors in front of cabinet for easy service access.
Heavy duty plastic drain pans on most models, powder coated galvanized steel horizontal drain pans standard on all.
Schrader provided for pressure assurance testing.
Multi-stage leak testing at 500 psi pressure decay, mass spectrometer tested with Helium, then Nitrogen pressurized and factory sealed for maximum reliability.
Aspen CE24A3N-145L-135
Item#:
CE24A3N-175L-135
Manufacturer Item:
CE24A3N-175L-135
Manufacturer:
ASPEN MFG. LLC
STANDARD SPECIFICATIONS
Rifled copper tubing, enhanced aluminum fins.
Immersion-tested at 500 psi, then nitrogen-pressurized and sealed.
Left- or right-hand refrigerant and plumbing connections.
Liquid line - 3/8 ODS, suction line - 3/4 ODS on 1-1/2- 3 ton & 7/8 ODS on 3-1/2 - 5 ton.
Externally mounted flowrater body with Schrader valve for hiss-testing.
Heavy duty plastic upflow drains pans on most models, powder coated galvanized steel horizontal
drain pans standard on all.
Embossed galvanized cabinets standard. Cabinets feature furnace connectors (patent pending).
Upflow, horizontal right, or horizontal left without field modification. Downflow applications require
plate kit, included.
Split access doors in front for easy service.
Fully insulated cabinets with faced insulation.
Ten-year limited warranty.
AHRI certifiable with all brands of A/C and heat pump systems.
ETL listed for use with R22 and R410a when proper metering device is used.
CE60A3G-245L-135
Item#:
CE60A3G-245L-135
Manufacturer Item:
CE60A3G-245L-135
Manufacturer:
ASPEN MFG. LLC
APPLICATION VERSATILITY
Standard Upflow without field modification. Downflow applications require field-installed downflow kit, sold separately.
AHRI certifiable with all brands of A/C and heat pump systems.
ETL listed for R22 and 410A. ETL listed for R454B and R32 with Refrigerant Detection System (RDS).
A2L refrigerants require a Refrigerant Detection System (RDS) for compliance.
A1 (R410A and R22) products manufactured in 2025 or later will be labeled as For servicing existing equipment only.
FEATURES
Rifled copper tubing, enhanced aluminum fins.
Fully insulated cabinets with faced insulation. Split access doors in front of cabinet for easy service access.
Heavy duty plastic drain pans on most models, powder coated galvanized steel horizontal drain pans standard on all.
Schrader provided for pressure assurance testing.
Multi-stage leak testing at 500 psi pressure decay, mass spectrometer tested with Helium, then Nitrogen pressurized and factory sealed for maximum reliability.
Aspen CE60A3N-210L-135
Item#:
CE60A3N-245L-135
Manufacturer Item:
CE60A3N-245L-135
Manufacturer:
ASPEN MFG. LLC
STANDARD SPECIFICATIONS
Rifled copper tubing, enhanced aluminum fins.
Immersion-tested at 500 psi, then nitrogen-pressurized and sealed.
Left- or right-hand refrigerant and plumbing connections.
Liquid line - 3/8 ODS, suction line - 3/4 ODS on 1-1/2- 3 ton & 7/8 ODS on 3-1/2 - 5 ton.
Externally mounted flowrater body with Schrader valve for hiss-testing.
Heavy duty plastic upflow drains pans on most models, powder coated galvanized steel horizontal
drain pans standard on all.
Embossed galvanized cabinets standard. Cabinets feature furnace connectors (patent pending).
Upflow, horizontal right, or horizontal left without field modification. Downflow applications require
plate kit, included.
Split access doors in front for easy service.
Fully insulated cabinets with faced insulation.
Ten-year limited warranty.
AHRI certifiable with all brands of A/C and heat pump systems.
ETL listed for use with R22 and R410a when proper metering device is used.
CE30A3G-145L-135
Item#:
CE30A3G-145L-135
Manufacturer Item:
CE30A3G-145L-135
Manufacturer:
ASPEN MFG. LLC
STANDARD SPECIFICATIONS
Rifled copper tubing, enhanced aluminum fins.
Immersion-tested at 500 psi, then nitrogen-pressurized and sealed.
Left- or right-hand refrigerant and plumbing connections.
Liquid line - 3/8 ODS, suction line - 3/4 ODS on 1-1/2- 3 ton & 7/8 ODS on 3-1/2 - 5 ton.
Externally mounted flowrater body with Schrader valve for hiss-testing.
Heavy duty plastic upflow drains pans on most models, powder coated galvanized steel horizontal
drain pans standard on all.
Embossed galvanized cabinets standard. Cabinets feature furnace connectors (patent pending).
Upflow, horizontal right, or horizontal left without field modification. Downflow applications require
plate kit, included.
Split access doors in front for easy service.
Fully insulated cabinets with faced insulation.
Ten-year limited warranty.
AHRI certifiable with all brands of A/C and heat pump systems.
ETL listed for use with R22 and R410a when proper metering device is used.
CE24A3G-145L-135
Item#:
CE24A3G-145L-135
Manufacturer Item:
CE24A3G-145L-135
Manufacturer:
ASPEN MFG. LLC
APPLICATION VERSATILITY
Standard Upflow without field modification. Downflow applications require field-installed downflow kit, sold separately.
AHRI certifiable with all brands of A/C and heat pump systems.
ETL listed for R22 and 410A. ETL listed for R454B and R32 with Refrigerant Detection System (RDS).
A2L refrigerants require a Refrigerant Detection System (RDS) for compliance.
A1 (R410A and R22) products manufactured in 2025 or later will be labeled as For servicing existing equipment only.
FEATURES
Rifled copper tubing, enhanced aluminum fins.
Fully insulated cabinets with faced insulation. Split access doors in front of cabinet for easy service access.
Heavy duty plastic drain pans on most models, powder coated galvanized steel horizontal drain pans standard on all.
Schrader provided for pressure assurance testing.
Multi-stage leak testing at 500 psi pressure decay, mass spectrometer tested with Helium, then Nitrogen pressurized and factory sealed for maximum reliability.
Aspen CE36A3N-175L-135
Item#:
CE36A3N-210L-135
Manufacturer Item:
CE36A3N-210L-135
Manufacturer:
ASPEN MFG. LLC