Home  > CARLIN COMBUSTION TECHNOLOGY(x)
|◀ 25 - 36 of 146 ▶|
View:
Carlin Parts R77-34 Ignitor Kit,
,



Carlin Parts R77-34


Carlin Parts R77-34

Item#:
R77-34
Manufacturer Item:
41000S0KIT
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
Carlin Parts R77-32 Ignitor Carlin,
,



Carlin Parts R77-32


Carlin Parts R77-32

Item#:
R77-32
Manufacturer Item:
41000S0CAS
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
Carlin Parts R77-31 Beckett A Base Ignitor

carlin parts r77-31

Item#:
R77-31
Manufacturer Item:
41000S0BK1
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
Carlin Parts 6020002S015120 CAD Cell Oil Primary Control, 15 sec Trial
  • Interrupted duty ignition
  • Recycle on flame failure
  • Serviceman reset protection (latch-up after 3-consecutive lockouts)
  • Diagnostic LED
  • Valve delay on/motor delay off (pre/post-purge)
  • 15 sec trial for ignition (TFI) other timings available
  • 1.3 sec flame failure response time (FFRT)
  • Alarm contacts
  • Thermostat/aquastat compatible
  • SMC (safety monitoring circuit) technology
,
,



R77-44


R77-44

Item#:
R77-44
Manufacturer Item:
6020002S015120
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
Carlin Parts R77-43 Carlin Base Plate 201/301 CRD

R77-43

Item#:
R77-43
Manufacturer Item:
4102000CSC
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
Carlin Parts Combustion Technology, Inc. the industrys technological leader in oil and gas, residential and commercial burners, controls and igniters.
  • Interrupted duty ignition for high efficiency
  • SMC technology for safety monitoring
  • LED indicators, alarm contacts and pump prime for economic as well as efficient performance
  • Serviceman reset protection ( latch-up after three consecutive lockouts)
  • 15 sec trial for ignition (TFI) other timings available
  • It offers recycle on flame failure and 1.3 sec flame failure response time
  • Oil primary control has a input voltage rating of 120 VAC, input frequency rating of 60 Hz and input power rating of 9 VA
  • It has a temperature rating of 32 - 140 deg F, resistive rating of 1500 ohm and safety switch timing of 15 sec
  • Primary control offers serviceman reset protection and valve delay on/motor delay off feature
  • It has a motor load of 10 FLA/60 LRA, ignitor load of 120 VAC at 60 Hz and valve load of 120 VAC at 60 Hz
  • 500 VA motor load
  • 24 VAC/VDC, 2 amp alarm contacts
  • Flame signal test jack
Sid Harvey Item #:R77-41: Replaces Part #:'s : 7G998,
,



carlin parts r77-41


carlin parts r77-41

Item#:
R77-41
Manufacturer Item:
6020002S
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
Carlin Parts 50200-02S CAD Cell Oil Primary Control for Oil and Gas, Residential and Commercial Burners, Controls and Igniters
  • Interrupted duty ignition
  • Recycle on flame failure
  • Serviceman reset protection (latch-up after 3-consecutive lockouts)
  • Diagnostic LED
  • 15 sec trial for ignition (TFI) other timings available
  • 1.3 sec flame failure response time (FFRT)
  • Alarm contacts
  • Thermostat/aquastat compatible
  • SMC (safety monitoring circuit) technology
,
,



carlin parts r77-40


carlin parts r77-40

Item#:
R77-40
Manufacturer Item:
5020002S
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
Carlin Parts 48245S Intermittent Duty Oil Burner Primary Control, 120 VAC
  • 45 sec trial for ignition
  • Red LED lockout indicator
  • Thermostat/aquastat compatible SMC (safety monitoring circuit) technology
  • 5 amp full load, 60 amp locked rotor motor load
  • 120 VAC, 60 Hz, 500 VA igniter load
Sid Harvey Item #:R75-47: Replaces Part #:'s : 7G193,

,



carlin parts r75-47


carlin parts r75-47

Item#:
R75-47
Manufacturer Item:
48245S
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
Carlin Parts 42230-02S CAD Cell Oil Primary Control for Thermostat/Aquastat Compatible, 120 VAC, 500 watt
  • Interrupted duty ignition for high efficiency
  • SMC technology for safety monitoring
  • Diagnostic LED indicators
  • Secondary burner control has a input voltage rating of 120 VAC, input frequency rating of 60 Hz and input power rating of 10 VA from limit circuit
  • 15 sec trial for Ignition 40200 (1.3 sec flame failure response time (FFRT))
  • 30 sec trial for Ignition 42230 (1.3 sec flame failure response time (FFRT)
  • Recycle on flame failure
  • It has a temperature rating of 32 - 140 deg F and resistive rating of 1500 ohm
  • Valve delay on/motor delay off for economic as well as efficient performance
  • It has a motor load of 10 FLA/60 LRA and ignitor load of 120 VAC at 60 Hz
  • 500 VA motor load
Sid Harvey Item #:R75-45: Replaces Part #:'s : 4H638,

,



carlin parts r75-45


carlin parts r75-45

Item#:
R75-45
Manufacturer Item:
4223002S
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
Item#:
R77-13
Carlin Parts R77-11 Ignitor Carlin 201-310CRD,
,



Carlin Parts R77-11


Carlin Parts R77-11

Item#:
R77-11
Manufacturer Item:
41000S0SC
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
Carlin Parts 40200-02S CAD Cell Oil Primary Control for Oil and Gas, Residential and Commercial Burners, Controls and Igniters
  • Interrupted duty ignition
  • 15 sec trial for Ignition 40200 (1.3 sec flame failure response time (FFRT))
  • Recycle on flame failure
  • Thermostat/aquastat compatible
  • SMC (safety monitoring circuit) technology
Sid Harvey Item #:R77-10: Replaces Part #:'s : 7G194,
,



carlin parts r77-10


carlin parts r77-10

Item#:
R77-10
Manufacturer Item:
40200-02S
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
|◀ 25 - 36 of 146 ▶|