S2K Commerce - Products Dropdown
S2K Commerce - Shopping Cart
S2K Commerce - Order Entry
Bosch Heating Parts 7738007396 Singular Manifold ,
Bosch Heating Parts 7738007396
Item#:
7738007396
Manufacturer Item:
7738007396
Manufacturer:
BOSCH THERMOTECHNOLOGY CORP
Bosch Heating Parts Oil Burner Riello F3B G115WS/3
7738007398
7738007398
Item#:
7738007398
Manufacturer Item:
7-738-007-398
Manufacturer:
BOSCH THERMOTECHNOLOGY CORP
Bosch Heating Parts Oil Burner Riello F5 G115/4
7738007399
7738007399
Item#:
7738007399
Manufacturer Item:
7-738-007-399
Manufacturer:
BOSCH THERMOTECHNOLOGY CORP
Bosch Heating Parts 7738007260 Electrode Assembly,
7738007260
Item#:
7738007260
Manufacturer Item:
7738007260
Manufacturer:
BOSCH THERMOTECHNOLOGY CORP
Flow Rate
- Atomizing noz.zles are available in a wide range of flow rates, all but eliminating the need for specially calibrated noz.zles. Between 1.00 GPH and 2.00 GPH, for example, seven different flow rates are available. Generally, with hot water and warm air heat, the smallest firing rate that will adequately heat the house on the coldest day is the proper size to use and the most economical. Short on-cycles result in low efficiency. Another guideline is to select the flow rate that provides a reasonable stack temperature regardless of the connected load. (According to the New England Fuel Institute, aim for a stack temperature of 400°F or lower on matched packaged units or 500°F or lower on conversion burners.) If the boiler or furnace is undersized for the load, it may be necessary to fire for the load and ignore the efficiency
- Spray angles are available from 30° through 90° in most noz.zle sizes to meet the requirements of a wide variety of burner air patterns and combustion chambers. Usually it is desirable to fit the spray angle to the air pattern of the burner. In todays flame retention burner, it is possible to fire more than one spray angle with good results. Generally, round or square combustion chambers should be fired with 70° to 90° noz.zles. Long, narrow chambers usually require 30° to 60° spray angles.
- Burner air patterns are much like noz.zle spray patterns in that they fall into the same general classifications, either hollow or solid. As you would expect, a burner with a hollow air pattern generally requires a hollow cone fuel noz.zle. A burner with a solid air pattern will give highest efficiency with a solid cone noz.zle, but the flame will probably be longer
7747028943
Item#:
7747028943
Manufacturer Item:
7-747-028-943
Manufacturer:
BOSCH THERMOTECHNOLOGY CORP
Flow Rate
- Atomizing noz.zles are available in a wide range of flow rates, all but eliminating the need for specially calibrated noz.zles. Between 1.00 GPH and 2.00 GPH, for example, seven different flow rates are available. Generally, with hot water and warm air heat, the smallest firing rate that will adequately heat the house on the coldest day is the proper size to use and the most economical. Short on-cycles result in low efficiency. Another guideline is to select the flow rate that provides a reasonable stack temperature regardless of the connected load. (According to the New England Fuel Institute, aim for a stack temperature of 400°F or lower on matched packaged units or 500°F or lower on conversion burners.) If the boiler or furnace is undersized for the load, it may be necessary to fire for the load and ignore the efficiency
- Spray angles are available from 30° through 90° in most noz.zle sizes to meet the requirements of a wide variety of burner air patterns and combustion chambers. Usually it is desirable to fit the spray angle to the air pattern of the burner. In todays flame retention burner, it is possible to fire more than one spray angle with good results. Generally, round or square combustion chambers should be fired with 70° to 90° noz.zles. Long, narrow chambers usually require 30° to 60° spray angles.
- Burner air patterns are much like noz.zle spray patterns in that they fall into the same general classifications, either hollow or solid. As you would expect, a burner with a hollow air pattern generally requires a hollow cone fuel noz.zle. A burner with a solid air pattern will give highest efficiency with a solid cone noz.zle, but the flame will probably be longer
7747028944
Item#:
7747028944
Manufacturer Item:
7-747-028-944
Manufacturer:
BOSCH THERMOTECHNOLOGY CORP
Bosch Heating Parts 7736504944 WIFI Water Module,
7736504944
Item#:
7736504944
Manufacturer Item:
7736504944
Manufacturer:
BOSCH THERMOTECHNOLOGY CORP
Bosch Heating Parts 7736660260 Conversion Kit Natural Gas>Propane GC144/32
7736660260
Item#:
7736660260
Manufacturer Item:
7736660260
Manufacturer:
BOSCH THERMOTECHNOLOGY CORP
Bosch Heating Parts 7738007404 Oil Burner Riello F5 G215/3
7738007404
7738007404
Item#:
7738007404
Manufacturer Item:
7-738-007-404
Manufacturer:
BOSCH THERMOTECHNOLOGY CORP
Bosch Heating Parts Oil Burner Riello F5 G215/4
7738007405
7738007405
Item#:
7738007405
Manufacturer Item:
7-738-007-405
Manufacturer:
BOSCH THERMOTECHNOLOGY CORP
Bosch Heating Parts 7719002502 Greenstar Cleaning Tool,
7719002502
Item#:
7719002502
Manufacturer Item:
7719002502
Manufacturer:
BOSCH THERMOTECHNOLOGY CORP
Bosch Heating Parts 7747007982 Temperature Sensor R2107,
bosch heating parts 7747007982
Item#:
7747007982
Manufacturer Item:
7747007982
Manufacturer:
BOSCH THERMOTECHNOLOGY CORP
