ActionsResideo R7284U1004 Oil Burner Primary Control 15/30/45 Second Lockout Timing,
Item#:
R7284U1004
Manufacturer Item:
R7284U1004
Manufacturer:
HONEYWELL
Resideo R7284B1024 Oil Burner Primary Control 15 Second Lockout Timing Interrupted Ignition,
,
,
Honeywell R8184G4009 Non-Recycle Oil Burner Control with Safety Timing, 120/220/240 volt
,
- Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat
- Solid state flame sensing circuit
- LED on terminal strip indicates system lockout
- Remote lockout indication
- Enclosed safety switch with external reset button
- Manual trip lever opens safety switch for system maintenance
- Mounts on standard 4 x 4" junction box
- C554A cadmium sulfide flame detector and 24 VAC thermostat required
- With 15 sec safety timing, alarm outputs and manual safety switch
,
Item#:
R75-40
Manufacturer Item:
R8184G4009
Manufacturer:
HONEYWELL
Honeywell Protectorelay R8184M1051 Oil Burner Control for Boilers, 120 - 240 VAC
,
- Operates the oil burner and oil valve (if desired) in response to a call for heat from a low voltage control circuit
- Intermittent ignition is on while the burner is on
- Solid state flame sensing circuit
- External button to manually reset safety switch after lockout
- Enclosed safety switch must be manually reset after safety shutdown
- R8184M includes 40 VA transformer and Y and G terminals for connection of cooling equipment
- Mounts on standard 4 x 4" junction box
- C554A cadmium sulfide flame detector and 24 VAC thermostat required
,
Honeywell Protectorelay R8184G4082 Oil Burner Control
,
- With 45 sec safety timing and alarm outputs
- Provides automatic, nonrecycling control of an intermittent ignition oil burner system
- Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat
- Solid state flame sensing circuit
- Enclosed safety switch with external reset button
- Manual trip lever opens safety switch for system maintenance
- Mounts on standard 4 x 4" junction box, select models may be mounted directly on burner housing
- C554A cadmium sulfide flame detector and 24 VAC thermostat required
- 75 VA at 120/240 VAC, 50-60 Hz, 25 VA at 24V, 50-60 Hz alarm load ratings(pilot duty)
,
Honeywell Protectorelay R8184G4066/U Non-Recycle Oil Burner Control with Safety Timing, 4-1/8" W x 4-3/8" H x 2-1/2" Depth
,
- Provides automatic, non-recycling control of an intermittent ignition oil burner system
- Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat
- Solid state flame sensing circuit
- LED on terminal strip indicates system lockout
- Remote lockout indication
- Enclosed safety switch with external reset button
- Manual trip lever opens safety switch for system maintenance
- Mounts on standard 4 x 4" junction box (select models may be mounted directly on burner housing)
- C554A cadmium sulfide flame detector and 24 volts thermostat required
- 15 second safety timing, alarm outputs, and manual safety switch
- Intermittent ignition timing
,
Resideo 390686-36 Orifice for Q314 Q345 and Q3450 Pilot Burner 0.011" Propane
Resideo 390686-36
Item#:
390686-36
Manufacturer Item:
390686-36
Manufacturer:
HONEYWELL
The ZD is a power close and spring open damper. It has a 24-volt motor used to control circulating air in HVAC systems and used when a normally-open damper is required. The ZD is typically used with the TrueZONE and other electronic zoning systems.
- Mechanical visual position indicator for damper status
- Solid construction using extruded aluminum frame and blades
- Parallel blade design for low leakage performance
- Simple, easy-to wire, two wire installation with a third wire option M4 for LED open only light
- Reliable, strong, 24 volt spring return motor
- Fail-safe, normally open operation
- Ordering instructions: order ZD (dimensions 1) x (dimensions 2), (motor is always mounted on dimensions 2 side) for example, ZD10x8 is a 10 x 8 Inch damper with the motor on the 8 Inch side, but a ZD8x10 is an 8 x 10 Inch damper that has the motor on the 10 Inch side
- Damper can be installed in any orientation (mounting side can be on either the bottom or the side of the duct)
- Motor or actuators mounting - side or top
- 30 sec power closed/10 sec spring return
- 90 deg angular rotation Honeywell Home TrueZone ZD Residential Damper, 10 x 12 Inch, Rectangular, 24 VAC, 0.32 amp, 90 deg Rotation, Import,
,
Item#:
ZD10X12TZ
Manufacturer Item:
ZD10X12TZ
Manufacturer:
HONEYWELL
ECR International Heating Parts 240009031 Pilot Assembly
Item#:
240009031
Manufacturer Item:
240-009031
Manufacturer:
HONEYWELL
ECR International Heating Parts 240011102 Pilot Assembly Q34521B2010
Item#:
240011102
Manufacturer Item:
240011102
Manufacturer:
HONEYWELL
Resideo Q314A6094 1-Left Direct Tip Pilot Burner W/Orifice for Q309 Q340 Q390,
Resideo Q345A1313 1-Left Direct Tip Pilot Burner W/Orifice for S86 S860 S8610 or,