S2K Commerce - Products Dropdown
S2K Commerce - Shopping Cart
S2K Commerce - Order Entry
Packard C330A 3-Pole Definite Purpose Contactor, 24 volt at 50/60 Hz, 30 amp
- 40 amp resistive, 180 amp at 240 volt, 150 amp at 480 volt, 120 amp at 600 volt locked rotor
- Coils have class B insulation
- Includes lug, spade terminals and covers
Packard C330A
Packard C220A 2-Pole Definite Purpose Contactor, 24 VAC at 50/60 Hz, 20 amp
- Includes lugs, spade terminals and covers
- Class B coil insulation
- 30 amp resistive, 120 amp at 240, 100 amp at 480 volt, 80 amp at 600 volt locked rotor
Packard C130B
Packard C130B 1-Pole Definite Purpose Contactor, 120 VAC at 50/60 Hz, 30 amp
,
- 30 amp full load inductive, 40 amp resistive, 180 amp at 240, 150 amp at 480 volt, 120 amp at 600 volt locked rotor
- Includes lugs, spade terminals and covers
- Coils have class B insulation
,
Motors & Armatures 62492
Packard C375C 3-Pole Definite Purpose Contactor, 208 - 240 VAC at 50/60 Hz, 75 amp
,
- 75 amp full load inductive, 90 amp resistive, 450 amp at 240, 375 amp at 480 volt, 300 amp at 600 volt locked rotor
- Includes lugs, spade terminals and covers
- Coils have class B insulation
,
Packard C375B
Packard C375B 3-Pole Definite Purpose Contactor, 120 VAC at 50/60 Hz, 75 amp
,
- 75 amp full load inductive, 90 amp resistive, 450 amp at 240, 375 amp at 480 volt, 300 amp at 600 volt locked rotor
- Includes lugs, spade terminals and covers
- Coils have class B insulation
,
Packard C360C
Packard C390C 3-Pole Definite Purpose Contactor, 208 - 240 VAC at 50/60 Hz, 90 amp
,
- 90 amp full load inductive, 120 amp resistive, 540 amp at 240 volt, 450 amp at 480 volt, 360 amp at 600 volt locked rotor
- Includes lugs, spade terminals and covers
- Coils have class B insulation
,
Packard C375C
Packard C360B 3-Pole Definite Purpose Contactor, 120 VAC at 50/60 Hz, 60 amp
,
- 60 amp full load inductive, 75 amp resistive, 360 amp at 240, 300 amp at 480 volt, 240 amp at 600 volt locked rotor
- Includes lugs, spade terminals and covers
- Coils have class B insulation
,
Packard C360A
Packard C360A 3-Pole Definite Purpose Contactor, 24 VAC at 50/60 Hz, 60 amp
,
- 60 amp full load inductive, 75 amp resistive, 360 amp at 240, 300 amp at 480 volt, 240 amp at 600 volt locked rotor
- Includes lugs, spade terminals and covers
- Coils have class B insulation
,
Packard C350C
Packard C360C 3-Pole Definite Purpose Contactor, 208/240 volt at 50/60 Hz, 60 amp
,
- Includes lug, spade terminals and covers
- Coils have class B insulation
- 75 amp resistive, 360 amp at 240 volt, 300 amp at 480 volt, 240 amp at 600 volt locked rotor
,
Packard C360B
Packard EBM10847 Wiring Harnesses For EBM9137 and EBM9538 Fans
Packard EBM10847
Packard Inducer Motor HC21ZE118 Draft Inducer Fan Motor 1/30 HP 120 VAC 2800/2500 RPM CW Ball Bearing
Packard Inducer Motor 82999
Packard KLK002 Midget Fuse Fast Acting 2 Amp 600 VAC
The KLK series fast-acting fuses are designed specifically for the protection of control circuits, street lighting, HID lighting, computers, and other applications without high in-rush currents. These midget fuses also have high-interrupting and currentlimiting capability. They are intended to supplement the primary branch-circuit fuse or breaker to provide backup overcurrent protection. The KLK fuses are non-indicating and may be used with an indicating fuse block to identify a blown fuse.
The KLK series fast-acting fuses are designed specifically for the protection of control circuits, street lighting, HID lighting, computers, and other applications without high in-rush currents. These midget fuses also have high-interrupting and currentlimiting capability. They are intended to supplement the primary branch-circuit fuse or breaker to provide backup overcurrent protection. The KLK fuses are non-indicating and may be used with an indicating fuse block to identify a blown fuse.