S2K Commerce - Products Dropdown
S2K Commerce - Shopping Cart
S2K Commerce - Order Entry
York PH3E36N00S21
Item#:
PH3E36N00S21
Manufacturer Item:
PH3E36N00S21
Manufacturer:
BHC RESIDENTIAL AND LIGHT COMM
Proven quality construction
Next-generation, high-efficiency blower delivers reduced energy consumption
Advanced fan design and vibration-reducing technology minimize noise for peace and quiet
Stainless-steel heat exchanger
Durable powder-coat paint is 1,000-hour salt-spray rated and in a sleek new color
Efficient performance
5.2 SEER2 models meet CEE Tier 1 eligibility requirements for 25C Federal
Tax Credits and other rebates/incentives
Easy installation and servicing
Single- and three-phase models available for
residential and light-commercial applications
Individual panels and front-facing components
for easy access
Convertible airflow design allows upflow,
downflow or horizontal applications
Easy-to-read, color-coded wiring diagrams
York PG3E60L12S31
Item#:
PG3E60L12S31
Manufacturer Item:
PG3E60L12S31
Manufacturer:
BHC RESIDENTIAL AND LIGHT COMM
Proven quality construction
Next-generation, high-efficiency blower delivers reduced energy consumption
Advanced fan design and vibration-reducing technology minimize noise for peace and quiet
Stainless-steel heat exchanger
Durable powder-coat paint is 1,000-hour salt-spray rated and in a sleek new color
Efficient performance
5.2 SEER2 models meet CEE Tier 1 eligibility requirements for 25C Federal
Tax Credits and other rebates/incentives
Easy installation and servicing
Single- and three-phase models available for
residential and light-commercial applications
Individual panels and front-facing components
for easy access
Convertible airflow design allows upflow,
downflow or horizontal applications
Easy-to-read, color-coded wiring diagrams
York PG3E36L07S31
Item#:
PG3E36L07S31
Manufacturer Item:
PG3E36L07S31
Manufacturer:
BHC RESIDENTIAL AND LIGHT COMM
Features
Easily applied in upflow, horizontal left or horizontal right, or downflow installation with minimal
conversion necessary.
Venting kit for downflow (counter-flow) applications on B, C, and D cabinets where side
discharge is not possible.
The unit cabinet is compact and easy to install with an ideal height of 33 in.
Full length fold-up duct connector flanges for application flexibility.
Easy access to controls to connect power and control wiring.
No electrical knockouts to deal with, making installation easier.
24 V, 40 VA control transformer and control provisions supplied for single or multi-stage add on
cooling.
Built-in, high level self diagnostics with fault code displays standard on integrated control
module for reliable operation.
Front-facing screws on flame sensor and hot surgace ignitor for ease of service.
Front-facing screws on blower assembly for easy access and removal of blower.
Constant torque blower motor for cooling SEER2 enhancement.
Blower-off delay for cooling SEER2 improvement.
Continuous fan options for indoor air quality (IAQ) performance.
Airflow leakage less than 2% of nominal airflow for duct performance testing conditions.
Low unit current requirement for easy replacement application.
Electronic hot surface ignition saves fuel cost with increased dependability and reliability.
100% shut-off main gas valve for extra safety.
Inducer rotates for easy conversion of venting options.
The 26k model is not convertible for use with propane (LP) gas. All other models are fieldconvertible for use with propane (LP) gas with an optional propane accessory conversion kit.
Five-speed direct drive standard ECM blower motor.
Hi-tech tubular aluminized steel primary heat exchanger.
Corrosion resistant stainless steel secondary heat exchanger including rear cover pan and front
vestibule panel.
Quiet inducer operation.
Timed on, adjustable off blower capability for maximum comfort.
Blower door safety switch below the blower deck.
Solid removable bottom panel allows easy conversion for bottom return air applications.
Twinning terminal for controlling two identical models installed with a common duct system. No
external kit is required.
External air filters are used for maximum flexibility in meeting customers' IAQ needs.
1/4 turn knobs are provided for easy independent door removal.
Insulated blower compartment for thermal and acoustic performance.
Internal condensate trap design (patent pending) provides condensate management options
and is self priming to prevent nuisance problems.
Protection included from air intake, exhaust vent, or condensate blockage. Venting applications
may be installed as either two-pipe sealed combustion or single-pipe vent (except 26k) using
indoor combustion air.
No special vent termination required.
These condensing furnace models produce <40 ng/J NOx emissions.
Fold-up duct connector flanges for application flexibility.
Patented self-priming internal condensate trap design for easy installation.
York RG19080C20MPS1
Item#:
RG19080C20MPS1
Manufacturer Item:
RG19080C20MPS1
Manufacturer:
BHC RESIDENTIAL AND LIGHT COMM
Features
Easily applied in upflow, horizontal left or horizontal right, or downflow installation with minimal
conversion necessary.
Venting kit for downflow (counter-flow) applications on B, C, and D cabinets where side
discharge is not possible.
The unit cabinet is compact and easy to install with an ideal height of 33 in.
Full length fold-up duct connector flanges for application flexibility.
Easy access to controls to connect power and control wiring.
No electrical knockouts to deal with, making installation easier.
24 V, 40 VA control transformer and control provisions supplied for single or multi-stage add on
cooling.
Built-in, high level self diagnostics with fault code displays standard on integrated control
module for reliable operation.
Front-facing screws on flame sensor and hot surgace ignitor for ease of service.
Front-facing screws on blower assembly for easy access and removal of blower.
Constant torque blower motor for cooling SEER2 enhancement.
Blower-off delay for cooling SEER2 improvement.
Continuous fan options for indoor air quality (IAQ) performance.
Airflow leakage less than 2% of nominal airflow for duct performance testing conditions.
Low unit current requirement for easy replacement application.
Electronic hot surface ignition saves fuel cost with increased dependability and reliability.
100% shut-off main gas valve for extra safety.
Inducer rotates for easy conversion of venting options.
The 26k model is not convertible for use with propane (LP) gas. All other models are fieldconvertible for use with propane (LP) gas with an optional propane accessory conversion kit.
Five-speed direct drive standard ECM blower motor.
Hi-tech tubular aluminized steel primary heat exchanger.
Corrosion resistant stainless steel secondary heat exchanger including rear cover pan and front
vestibule panel.
Quiet inducer operation.
Timed on, adjustable off blower capability for maximum comfort.
Blower door safety switch below the blower deck.
Solid removable bottom panel allows easy conversion for bottom return air applications.
Twinning terminal for controlling two identical models installed with a common duct system. No
external kit is required.
External air filters are used for maximum flexibility in meeting customers' IAQ needs.
1/4 turn knobs are provided for easy independent door removal.
Insulated blower compartment for thermal and acoustic performance.
Internal condensate trap design (patent pending) provides condensate management options
and is self priming to prevent nuisance problems.
Protection included from air intake, exhaust vent, or condensate blockage. Venting applications
may be installed as either two-pipe sealed combustion or single-pipe vent (except 26k) using
indoor combustion air.
No special vent termination required.
These condensing furnace models produce <40 ng/J NOx emissions.
Fold-up duct connector flanges for application flexibility.
Patented self-priming internal condensate trap design for easy installation.
York RG19060B12MPS1
Item#:
RG19060B12MPS1
Manufacturer Item:
RG19060B12MPS1
Manufacturer:
BHC RESIDENTIAL AND LIGHT COMM
Features
Easily applied in upflow, horizontal left or horizontal right, or downflow installation with minimal
conversion necessary.
Venting kit for downflow (counter-flow) applications on B, C, and D cabinets where side
discharge is not possible.
The unit cabinet is compact and easy to install with an ideal height of 33 in.
Full length fold-up duct connector flanges for application flexibility.
Easy access to controls to connect power and control wiring.
No electrical knockouts to deal with, making installation easier.
24 V, 40 VA control transformer and control provisions supplied for single or multi-stage add on
cooling.
Built-in, high level self diagnostics with fault code displays standard on integrated control
module for reliable operation.
Front-facing screws on flame sensor and hot surgace ignitor for ease of service.
Front-facing screws on blower assembly for easy access and removal of blower.
Constant torque blower motor for cooling SEER2 enhancement.
Blower-off delay for cooling SEER2 improvement.
Continuous fan options for indoor air quality (IAQ) performance.
Airflow leakage less than 2% of nominal airflow for duct performance testing conditions.
Low unit current requirement for easy replacement application.
Electronic hot surface ignition saves fuel cost with increased dependability and reliability.
100% shut-off main gas valve for extra safety.
Inducer rotates for easy conversion of venting options.
The 26k model is not convertible for use with propane (LP) gas. All other models are fieldconvertible for use with propane (LP) gas with an optional propane accessory conversion kit.
Five-speed direct drive standard ECM blower motor.
Hi-tech tubular aluminized steel primary heat exchanger.
Corrosion resistant stainless steel secondary heat exchanger including rear cover pan and front
vestibule panel.
Quiet inducer operation.
Timed on, adjustable off blower capability for maximum comfort.
Blower door safety switch below the blower deck.
Solid removable bottom panel allows easy conversion for bottom return air applications.
Twinning terminal for controlling two identical models installed with a common duct system. No
external kit is required.
External air filters are used for maximum flexibility in meeting customers' IAQ needs.
1/4 turn knobs are provided for easy independent door removal.
Insulated blower compartment for thermal and acoustic performance.
Internal condensate trap design (patent pending) provides condensate management options
and is self priming to prevent nuisance problems.
Protection included from air intake, exhaust vent, or condensate blockage. Venting applications
may be installed as either two-pipe sealed combustion or single-pipe vent (except 26k) using
indoor combustion air.
No special vent termination required.
These condensing furnace models produce <40 ng/J NOx emissions.
Fold-up duct connector flanges for application flexibility.
Patented self-priming internal condensate trap design for easy installation.
York RG19100C20MPS1
Item#:
RG19100C20MPS1
Manufacturer Item:
RG19100C20MPS1
Manufacturer:
BHC RESIDENTIAL AND LIGHT COMM
Features
Easily applied in upflow, horizontal left or horizontal right, or downflow installation with minimal
conversion necessary.
Venting kit for downflow (counter-flow) applications on B, C, and D cabinets where side
discharge is not possible.
The unit cabinet is compact and easy to install with an ideal height of 33 in.
Full length fold-up duct connector flanges for application flexibility.
Easy access to controls to connect power and control wiring.
No electrical knockouts to deal with, making installation easier.
24 V, 40 VA control transformer and control provisions supplied for single or multi-stage add on
cooling.
Built-in, high level self diagnostics with fault code displays standard on integrated control
module for reliable operation.
Front-facing screws on flame sensor and hot surgace ignitor for ease of service.
Front-facing screws on blower assembly for easy access and removal of blower.
Constant torque blower motor for cooling SEER2 enhancement.
Blower-off delay for cooling SEER2 improvement.
Continuous fan options for indoor air quality (IAQ) performance.
Airflow leakage less than 2% of nominal airflow for duct performance testing conditions.
Low unit current requirement for easy replacement application.
Electronic hot surface ignition saves fuel cost with increased dependability and reliability.
100% shut-off main gas valve for extra safety.
Inducer rotates for easy conversion of venting options.
The 26k model is not convertible for use with propane (LP) gas. All other models are fieldconvertible for use with propane (LP) gas with an optional propane accessory conversion kit.
Five-speed direct drive standard ECM blower motor.
Hi-tech tubular aluminized steel primary heat exchanger.
Corrosion resistant stainless steel secondary heat exchanger including rear cover pan and front
vestibule panel.
Quiet inducer operation.
Timed on, adjustable off blower capability for maximum comfort.
Blower door safety switch below the blower deck.
Solid removable bottom panel allows easy conversion for bottom return air applications.
Twinning terminal for controlling two identical models installed with a common duct system. No
external kit is required.
External air filters are used for maximum flexibility in meeting customers' IAQ needs.
1/4 turn knobs are provided for easy independent door removal.
Insulated blower compartment for thermal and acoustic performance.
Internal condensate trap design (patent pending) provides condensate management options
and is self priming to prevent nuisance problems.
Protection included from air intake, exhaust vent, or condensate blockage. Venting applications
may be installed as either two-pipe sealed combustion or single-pipe vent (except 26k) using
indoor combustion air.
No special vent termination required.
These condensing furnace models produce <40 ng/J NOx emissions.
Fold-up duct connector flanges for application flexibility.
Patented self-priming internal condensate trap design for easy installation.
York RG19080C16MPS1
Item#:
RG19080C16MPS1
Manufacturer Item:
RG19080C16MPS1
Manufacturer:
BHC RESIDENTIAL AND LIGHT COMM
Features
Easily applied in upflow, horizontal left or horizontal right, or downflow installation with minimal
conversion necessary.
Venting kit for downflow (counter-flow) applications on B, C, and D cabinets where side
discharge is not possible.
The unit cabinet is compact and easy to install with an ideal height of 33 in.
Full length fold-up duct connector flanges for application flexibility.
Easy access to controls to connect power and control wiring.
No electrical knockouts to deal with, making installation easier.
24 V, 40 VA control transformer and control provisions supplied for single or multi-stage add on
cooling.
Built-in, high level self diagnostics with fault code displays standard on integrated control
module for reliable operation.
Front-facing screws on flame sensor and hot surgace ignitor for ease of service.
Front-facing screws on blower assembly for easy access and removal of blower.
Constant torque blower motor for cooling SEER2 enhancement.
Blower-off delay for cooling SEER2 improvement.
Continuous fan options for indoor air quality (IAQ) performance.
Airflow leakage less than 2% of nominal airflow for duct performance testing conditions.
Low unit current requirement for easy replacement application.
Electronic hot surface ignition saves fuel cost with increased dependability and reliability.
100% shut-off main gas valve for extra safety.
Inducer rotates for easy conversion of venting options.
The 26k model is not convertible for use with propane (LP) gas. All other models are fieldconvertible for use with propane (LP) gas with an optional propane accessory conversion kit.
Five-speed direct drive standard ECM blower motor.
Hi-tech tubular aluminized steel primary heat exchanger.
Corrosion resistant stainless steel secondary heat exchanger including rear cover pan and front
vestibule panel.
Quiet inducer operation.
Timed on, adjustable off blower capability for maximum comfort.
Blower door safety switch below the blower deck.
Solid removable bottom panel allows easy conversion for bottom return air applications.
Twinning terminal for controlling two identical models installed with a common duct system. No
external kit is required.
External air filters are used for maximum flexibility in meeting customers' IAQ needs.
1/4 turn knobs are provided for easy independent door removal.
Insulated blower compartment for thermal and acoustic performance.
Internal condensate trap design (patent pending) provides condensate management options
and is self priming to prevent nuisance problems.
Protection included from air intake, exhaust vent, or condensate blockage. Venting applications
may be installed as either two-pipe sealed combustion or single-pipe vent (except 26k) using
indoor combustion air.
No special vent termination required.
These condensing furnace models produce <40 ng/J NOx emissions.
Fold-up duct connector flanges for application flexibility.
Patented self-priming internal condensate trap design for easy installation.
York RG19060A10MPS1
Item#:
RG19060A10MPS1
Manufacturer Item:
RG19060A10MPS1
Manufacturer:
BHC RESIDENTIAL AND LIGHT COMM
Features
Easily applied in upflow, horizontal left or horizontal right, or downflow installation with minimal
conversion necessary.
Venting kit for downflow (counter-flow) applications on B, C, and D cabinets where side
discharge is not possible.
The unit cabinet is compact and easy to install with an ideal height of 33 in.
Full length fold-up duct connector flanges for application flexibility.
Easy access to controls to connect power and control wiring.
No electrical knockouts to deal with, making installation easier.
24 V, 40 VA control transformer and control provisions supplied for single or multi-stage add on
cooling.
Built-in, high level self diagnostics with fault code displays standard on integrated control
module for reliable operation.
Front-facing screws on flame sensor and hot surgace ignitor for ease of service.
Front-facing screws on blower assembly for easy access and removal of blower.
Constant torque blower motor for cooling SEER2 enhancement.
Blower-off delay for cooling SEER2 improvement.
Continuous fan options for indoor air quality (IAQ) performance.
Airflow leakage less than 2% of nominal airflow for duct performance testing conditions.
Low unit current requirement for easy replacement application.
Electronic hot surface ignition saves fuel cost with increased dependability and reliability.
100% shut-off main gas valve for extra safety.
Inducer rotates for easy conversion of venting options.
The 26k model is not convertible for use with propane (LP) gas. All other models are fieldconvertible for use with propane (LP) gas with an optional propane accessory conversion kit.
Five-speed direct drive standard ECM blower motor.
Hi-tech tubular aluminized steel primary heat exchanger.
Corrosion resistant stainless steel secondary heat exchanger including rear cover pan and front
vestibule panel.
Quiet inducer operation.
Timed on, adjustable off blower capability for maximum comfort.
Blower door safety switch below the blower deck.
Solid removable bottom panel allows easy conversion for bottom return air applications.
Twinning terminal for controlling two identical models installed with a common duct system. No
external kit is required.
External air filters are used for maximum flexibility in meeting customers' IAQ needs.
1/4 turn knobs are provided for easy independent door removal.
Insulated blower compartment for thermal and acoustic performance.
Internal condensate trap design (patent pending) provides condensate management options
and is self priming to prevent nuisance problems.
Protection included from air intake, exhaust vent, or condensate blockage. Venting applications
may be installed as either two-pipe sealed combustion or single-pipe vent (except 26k) using
indoor combustion air.
No special vent termination required.
These condensing furnace models produce <40 ng/J NOx emissions.
Fold-up duct connector flanges for application flexibility.
Patented self-priming internal condensate trap design for easy installation.
York RG19120D20MPS1
Item#:
RG19120D20MPS1
Manufacturer Item:
RG19120D20MPS1
Manufacturer:
BHC RESIDENTIAL AND LIGHT COMM
Features
Easily applied in upflow, horizontal left or horizontal right, or downflow installation with minimal
conversion necessary.
Venting kit for downflow (counter-flow) applications on B, C, and D cabinets where side
discharge is not possible.
The unit cabinet is compact and easy to install with an ideal height of 33 in.
Full length fold-up duct connector flanges for application flexibility.
Easy access to controls to connect power and control wiring.
No electrical knockouts to deal with, making installation easier.
24 V, 40 VA control transformer and control provisions supplied for single or multi-stage add on
cooling.
Built-in, high level self diagnostics with fault code displays standard on integrated control
module for reliable operation.
Front-facing screws on flame sensor and hot surgace ignitor for ease of service.
Front-facing screws on blower assembly for easy access and removal of blower.
Constant torque blower motor for cooling SEER2 enhancement.
Blower-off delay for cooling SEER2 improvement.
Continuous fan options for indoor air quality (IAQ) performance.
Airflow leakage less than 2% of nominal airflow for duct performance testing conditions.
Low unit current requirement for easy replacement application.
Electronic hot surface ignition saves fuel cost with increased dependability and reliability.
100% shut-off main gas valve for extra safety.
Inducer rotates for easy conversion of venting options.
The 26k model is not convertible for use with propane (LP) gas. All other models are fieldconvertible for use with propane (LP) gas with an optional propane accessory conversion kit.
Five-speed direct drive standard ECM blower motor.
Hi-tech tubular aluminized steel primary heat exchanger.
Corrosion resistant stainless steel secondary heat exchanger including rear cover pan and front
vestibule panel.
Quiet inducer operation.
Timed on, adjustable off blower capability for maximum comfort.
Blower door safety switch below the blower deck.
Solid removable bottom panel allows easy conversion for bottom return air applications.
Twinning terminal for controlling two identical models installed with a common duct system. No
external kit is required.
External air filters are used for maximum flexibility in meeting customers' IAQ needs.
1/4 turn knobs are provided for easy independent door removal.
Insulated blower compartment for thermal and acoustic performance.
Internal condensate trap design (patent pending) provides condensate management options
and is self priming to prevent nuisance problems.
Protection included from air intake, exhaust vent, or condensate blockage. Venting applications
may be installed as either two-pipe sealed combustion or single-pipe vent (except 26k) using
indoor combustion air.
No special vent termination required.
These condensing furnace models produce <40 ng/J NOx emissions.
Fold-up duct connector flanges for application flexibility.
Patented self-priming internal condensate trap design for easy installation.
York RG19040A10MPS1
Item#:
RG19040A10MPS1
Manufacturer Item:
RG19040A10MPS1
Manufacturer:
BHC RESIDENTIAL AND LIGHT COMM
Features
Easily applied in upflow, horizontal left or horizontal right, or downflow installation with minimal
conversion necessary.
Venting kit for downflow (counter-flow) applications on B, C, and D cabinets where side
discharge is not possible.
The unit cabinet is compact and easy to install with an ideal height of 33 in.
Full length fold-up duct connector flanges for application flexibility.
Easy access to controls to connect power and control wiring.
No electrical knockouts to deal with, making installation easier.
24 V, 40 VA control transformer and control provisions supplied for single or multi-stage add on
cooling.
Built-in, high level self diagnostics with fault code displays standard on integrated control
module for reliable operation.
Front-facing screws on flame sensor and hot surgace ignitor for ease of service.
Front-facing screws on blower assembly for easy access and removal of blower.
Constant torque blower motor for cooling SEER2 enhancement.
Blower-off delay for cooling SEER2 improvement.
Continuous fan options for indoor air quality (IAQ) performance.
Airflow leakage less than 2% of nominal airflow for duct performance testing conditions.
Low unit current requirement for easy replacement application.
Electronic hot surface ignition saves fuel cost with increased dependability and reliability.
100% shut-off main gas valve for extra safety.
Inducer rotates for easy conversion of venting options.
The 26k model is not convertible for use with propane (LP) gas. All other models are fieldconvertible for use with propane (LP) gas with an optional propane accessory conversion kit.
Five-speed direct drive standard ECM blower motor.
Hi-tech tubular aluminized steel primary heat exchanger.
Corrosion resistant stainless steel secondary heat exchanger including rear cover pan and front
vestibule panel.
Quiet inducer operation.
Timed on, adjustable off blower capability for maximum comfort.
Blower door safety switch below the blower deck.
Solid removable bottom panel allows easy conversion for bottom return air applications.
Twinning terminal for controlling two identical models installed with a common duct system. No
external kit is required.
External air filters are used for maximum flexibility in meeting customers' IAQ needs.
1/4 turn knobs are provided for easy independent door removal.
Insulated blower compartment for thermal and acoustic performance.
Internal condensate trap design (patent pending) provides condensate management options
and is self priming to prevent nuisance problems.
Protection included from air intake, exhaust vent, or condensate blockage. Venting applications
may be installed as either two-pipe sealed combustion or single-pipe vent (except 26k) using
indoor combustion air.
No special vent termination required.
These condensing furnace models produce <40 ng/J NOx emissions.
Fold-up duct connector flanges for application flexibility.
Patented self-priming internal condensate trap design for easy installation.
York RG19080B12MPS1
Item#:
RG19080B12MPS1
Manufacturer Item:
RG19080B12MPS1
Manufacturer:
BHC RESIDENTIAL AND LIGHT COMM
Features
Easily applied in upflow, horizontal left or horizontal right, or downflow installation with minimal
conversion necessary.
Venting kit for downflow (counter-flow) applications on B, C, and D cabinets where side
discharge is not possible.
The unit cabinet is compact and easy to install with an ideal height of 33 in.
Full length fold-up duct connector flanges for application flexibility.
Easy access to controls to connect power and control wiring.
No electrical knockouts to deal with, making installation easier.
24 V, 40 VA control transformer and control provisions supplied for single or multi-stage add on
cooling or heat pump heating.
Built-in, high level self diagnostics with fault code displays standard on integrated control
module for reliable operation.
Front-facing screws on flame sensor and hot surface ignitor for ease of service.
Front-facing screws on blower assembly for easy access and removal of blower.
Constant torque blower motor for cooling SEER2 enhancement.
Blower-off delay for cooling SEER2 improvement.
Continuous fan options for indoor air quality (IAQ) performance.
Airflow leakage less than 2% of nominal airflow for duct performance testing conditions.
Low unit current requirement for easy replacement application.
Electronic hot surface ignition saves fuel cost with increased dependability and reliability.
100% shut-off main gas valve for extra safety.
Inducer rotates for easy conversion of venting options.
Five-speed direct drive standard ECM blower motor.
Hi-tech tubular aluminized steel primary heat exchanger.
Corrosion resistant stainless steel secondary heat exchanger including rear cover pan and front
vestibule panel.
Quiet inducer operation.
York RL18080C16MPS1
Item#:
RL18080C16MPS1
Manufacturer Item:
RL18080C16MPS1
Manufacturer:
BHC RESIDENTIAL AND LIGHT COMM