Home  > JC RESIDENTIAL AND LIGHT COMME(x)
|◀ 25 - 36 of 43 ▶|
View:
Features
  • Easily applied in upflow, horizontal left or horizontal right, or downflow installation with minimal conversion necessary. Venting kit for downflow (counter-flow) applications on B, C, and D cabinets where side discharge is not possible.
  • The unit cabinet is compact and easy to install with an ideal height of 33 in.
  • Full length fold-up duct connector flanges for application flexibility.
  • Easy access to controls to connect power and control wiring.
  • No electrical knockouts to deal with, making installation easier.
  • 24 V, 40 VA control transformer and control provisions supplied for single or multi-stage add on cooling.
  • Built-in, high level self diagnostics with fault code displays standard on integrated control module for reliable operation.
  • Front-facing screws on flame sensor and hot surgace ignitor for ease of service.
  • Front-facing screws on blower assembly for easy access and removal of blower.
  • Constant torque blower motor for cooling SEER2 enhancement.
  • Blower-off delay for cooling SEER2 improvement.
  • Continuous fan options for indoor air quality (IAQ) performance.
  • Airflow leakage less than 2% of nominal airflow for duct performance testing conditions.
  • Low unit current requirement for easy replacement application.
  • Electronic hot surface ignition saves fuel cost with increased dependability and reliability.
  • 100% shut-off main gas valve for extra safety.
  • Inducer rotates for easy conversion of venting options.
  • The 26k model is not convertible for use with propane (LP) gas. All other models are fieldconvertible for use with propane (LP) gas with an optional propane accessory conversion kit.
  • Five-speed direct drive standard ECM blower motor.
  • Hi-tech tubular aluminized steel primary heat exchanger.
  • Corrosion resistant stainless steel secondary heat exchanger including rear cover pan and front vestibule panel.
  • Quiet inducer operation.
  • Timed on, adjustable off blower capability for maximum comfort.
  • Blower door safety switch below the blower deck.
  • Solid removable bottom panel allows easy conversion for bottom return air applications.
  • Twinning terminal for controlling two identical models installed with a common duct system. No external kit is required.
  • External air filters are used for maximum flexibility in meeting customers' IAQ needs.
  • 1/4 turn knobs are provided for easy independent door removal.
  • Insulated blower compartment for thermal and acoustic performance.
  • Internal condensate trap design (patent pending) provides condensate management options and is self priming to prevent nuisance problems.
  • Protection included from air intake, exhaust vent, or condensate blockage. Venting applications may be installed as either two-pipe sealed combustion or single-pipe vent (except 26k) using indoor combustion air.
  • No special vent termination required.
  • These condensing furnace models produce <40 ng/J NOx emissions.
  • Fold-up duct connector flanges for application flexibility.
  • Patented self-priming internal condensate trap design for easy installation.

    York RG19060A10MPS1

  • Item#:
    RG19060B12MPS1
    Manufacturer Item:
    RG19060B12MPS1
    Manufacturer:
    JC RESIDENTIAL AND LIGHT COMME
    Features
  • Easily applied in upflow, horizontal left or horizontal right, or downflow installation with minimal conversion necessary.
  • Venting kit for downflow (counter-flow) applications on B, C, and D cabinets where side discharge is not possible.
  • The unit cabinet is compact and easy to install with an ideal height of 33 in.
  • Full length fold-up duct connector flanges for application flexibility.
  • Easy access to controls to connect power and control wiring.
  • No electrical knockouts to deal with, making installation easier.
  • 24 V, 40 VA control transformer and control provisions supplied for single or multi-stage add on cooling or heat pump heating.
  • Built-in, high level self diagnostics with fault code displays standard on integrated control module for reliable operation.
  • Front-facing screws on flame sensor and hot surface ignitor for ease of service.
  • Front-facing screws on blower assembly for easy access and removal of blower.
  • Constant torque blower motor for cooling SEER2 enhancement.
  • Blower-off delay for cooling SEER2 improvement.
  • Continuous fan options for indoor air quality (IAQ) performance.
  • Airflow leakage less than 2% of nominal airflow for duct performance testing conditions.
  • Low unit current requirement for easy replacement application.
  • Electronic hot surface ignition saves fuel cost with increased dependability and reliability.
  • 100% shut-off main gas valve for extra safety.
  • Inducer rotates for easy conversion of venting options.
  • Five-speed direct drive standard ECM blower motor.
  • Hi-tech tubular aluminized steel primary heat exchanger.
  • Corrosion resistant stainless steel secondary heat exchanger including rear cover pan and front vestibule panel.
  • Quiet inducer operation.

    York RL18080B12MPS1

  • Item#:
    RL18080C16MPS1
    Manufacturer Item:
    RL18080C16MPS1
    Manufacturer:
    JC RESIDENTIAL AND LIGHT COMME
    Features
  • Easily applied in upflow, horizontal left or horizontal right, or downflow installation with minimal conversion necessary.
  • Venting kit for downflow (counter-flow) applications on B, C, and D cabinets where side discharge is not possible.
  • The unit cabinet is compact and easy to install with an ideal height of 33 in.
  • Full length fold-up duct connector flanges for application flexibility.
  • Easy access to controls to connect power and control wiring.
  • No electrical knockouts to deal with, making installation easier.
  • 24 V, 40 VA control transformer and control provisions supplied for single or multi-stage add on cooling or heat pump heating.
  • Built-in, high level self diagnostics with fault code displays standard on integrated control module for reliable operation.
  • Front-facing screws on flame sensor and hot surface ignitor for ease of service.
  • Front-facing screws on blower assembly for easy access and removal of blower.
  • Constant torque blower motor for cooling SEER2 enhancement.
  • Blower-off delay for cooling SEER2 improvement.
  • Continuous fan options for indoor air quality (IAQ) performance.
  • Airflow leakage less than 2% of nominal airflow for duct performance testing conditions.
  • Low unit current requirement for easy replacement application.
  • Electronic hot surface ignition saves fuel cost with increased dependability and reliability.
  • 100% shut-off main gas valve for extra safety.
  • Inducer rotates for easy conversion of venting options.
  • Five-speed direct drive standard ECM blower motor.
  • Hi-tech tubular aluminized steel primary heat exchanger.
  • Corrosion resistant stainless steel secondary heat exchanger including rear cover pan and front vestibule panel.
  • Quiet inducer operation.

    York RL18040A12MPS1

  • Item#:
    RL18080B12MPS1
    Manufacturer Item:
    RL18080B12MPS1
    Manufacturer:
    JC RESIDENTIAL AND LIGHT COMME
    Features
  • Easily applied in upflow, horizontal left or horizontal right, or downflow installation with minimal conversion necessary. Venting kit for downflow (counter-flow) applications on B, C, and D cabinets where side discharge is not possible.
  • The unit cabinet is compact and easy to install with an ideal height of 33 in.
  • Full length fold-up duct connector flanges for application flexibility.
  • Easy access to controls to connect power and control wiring.
  • No electrical knockouts to deal with, making installation easier.
  • 24 V, 40 VA control transformer and control provisions supplied for single or multi-stage add on cooling.
  • Built-in, high level self diagnostics with fault code displays standard on integrated control module for reliable operation.
  • Front-facing screws on flame sensor and hot surgace ignitor for ease of service.
  • Front-facing screws on blower assembly for easy access and removal of blower.
  • Constant torque blower motor for cooling SEER2 enhancement.
  • Blower-off delay for cooling SEER2 improvement.
  • Continuous fan options for indoor air quality (IAQ) performance.
  • Airflow leakage less than 2% of nominal airflow for duct performance testing conditions.
  • Low unit current requirement for easy replacement application.
  • Electronic hot surface ignition saves fuel cost with increased dependability and reliability.
  • 100% shut-off main gas valve for extra safety.
  • Inducer rotates for easy conversion of venting options.
  • The 26k model is not convertible for use with propane (LP) gas. All other models are fieldconvertible for use with propane (LP) gas with an optional propane accessory conversion kit.
  • Five-speed direct drive standard ECM blower motor.
  • Hi-tech tubular aluminized steel primary heat exchanger.
  • Corrosion resistant stainless steel secondary heat exchanger including rear cover pan and front vestibule panel.
  • Quiet inducer operation.
  • Timed on, adjustable off blower capability for maximum comfort.
  • Blower door safety switch below the blower deck.
  • Solid removable bottom panel allows easy conversion for bottom return air applications.
  • Twinning terminal for controlling two identical models installed with a common duct system. No external kit is required.
  • External air filters are used for maximum flexibility in meeting customers' IAQ needs.
  • 1/4 turn knobs are provided for easy independent door removal.
  • Insulated blower compartment for thermal and acoustic performance.
  • Internal condensate trap design (patent pending) provides condensate management options and is self priming to prevent nuisance problems.
  • Protection included from air intake, exhaust vent, or condensate blockage. Venting applications may be installed as either two-pipe sealed combustion or single-pipe vent (except 26k) using indoor combustion air.
  • No special vent termination required.
  • These condensing furnace models produce <40 ng/J NOx emissions.
  • Fold-up duct connector flanges for application flexibility.
  • Patented self-priming internal condensate trap design for easy installation.

    York RG19080C20MPS1

  • Item#:
    RG19100C20MPS1
    Manufacturer Item:
    RG19100C20MPS1
    Manufacturer:
    JC RESIDENTIAL AND LIGHT COMME
    Features
  • Easily applied in upflow, horizontal left or horizontal right, or downflow installation with minimal conversion necessary.
  • Venting kit for downflow (counter-flow) applications on B, C, and D cabinets where side discharge is not possible.
  • The unit cabinet is compact and easy to install with an ideal height of 33 in.
  • Full length fold-up duct connector flanges for application flexibility.
  • Easy access to controls to connect power and control wiring.
  • No electrical knockouts to deal with, making installation easier.
  • 24 V, 40 VA control transformer and control provisions supplied for single or multi-stage add on cooling or heat pump heating.
  • Built-in, high level self diagnostics with fault code displays standard on integrated control module for reliable operation.
  • Front-facing screws on flame sensor and hot surface ignitor for ease of service.
  • Front-facing screws on blower assembly for easy access and removal of blower.
  • Constant torque blower motor for cooling SEER2 enhancement.
  • Blower-off delay for cooling SEER2 improvement.
  • Continuous fan options for indoor air quality (IAQ) performance.
  • Airflow leakage less than 2% of nominal airflow for duct performance testing conditions.
  • Low unit current requirement for easy replacement application.
  • Electronic hot surface ignition saves fuel cost with increased dependability and reliability.
  • 100% shut-off main gas valve for extra safety.
  • Inducer rotates for easy conversion of venting options.
  • Five-speed direct drive standard ECM blower motor.
  • Hi-tech tubular aluminized steel primary heat exchanger.
  • Corrosion resistant stainless steel secondary heat exchanger including rear cover pan and front vestibule panel.
  • Quiet inducer operation.

    York RL18120C20MPS1

  • Item#:
    RL18130D20MPS1
    Manufacturer Item:
    RL18130D20MPS1
    Manufacturer:
    JC RESIDENTIAL AND LIGHT COMME
    Features
  • Easily applied in upflow, horizontal left or horizontal right, or downflow installation with minimal conversion necessary.
  • Venting kit for downflow (counter-flow) applications on B, C, and D cabinets where side discharge is not possible.
  • The unit cabinet is compact and easy to install with an ideal height of 33 in.
  • Full length fold-up duct connector flanges for application flexibility.
  • Easy access to controls to connect power and control wiring.
  • No electrical knockouts to deal with, making installation easier.
  • 24 V, 40 VA control transformer and control provisions supplied for single or multi-stage add on cooling or heat pump heating.
  • Built-in, high level self diagnostics with fault code displays standard on integrated control module for reliable operation.
  • Front-facing screws on flame sensor and hot surface ignitor for ease of service.
  • Front-facing screws on blower assembly for easy access and removal of blower.
  • Constant torque blower motor for cooling SEER2 enhancement.
  • Blower-off delay for cooling SEER2 improvement.
  • Continuous fan options for indoor air quality (IAQ) performance.
  • Airflow leakage less than 2% of nominal airflow for duct performance testing conditions.
  • Low unit current requirement for easy replacement application.
  • Electronic hot surface ignition saves fuel cost with increased dependability and reliability.
  • 100% shut-off main gas valve for extra safety.
  • Inducer rotates for easy conversion of venting options.
  • Five-speed direct drive standard ECM blower motor.
  • Hi-tech tubular aluminized steel primary heat exchanger.
  • Corrosion resistant stainless steel secondary heat exchanger including rear cover pan and front vestibule panel.
  • Quiet inducer operation.

    York RL18100C16MPS1

  • Item#:
    RL18120C20MPS1
    Manufacturer Item:
    RL18120C20MPS1
    Manufacturer:
    JC RESIDENTIAL AND LIGHT COMME
    Features
  • Easily applied in upflow, horizontal left or horizontal right, or downflow installation with minimal conversion necessary. Venting kit for downflow (counter-flow) applications on B, C, and D cabinets where side discharge is not possible.
  • The unit cabinet is compact and easy to install with an ideal height of 33 in.
  • Full length fold-up duct connector flanges for application flexibility.
  • Easy access to controls to connect power and control wiring.
  • No electrical knockouts to deal with, making installation easier.
  • 24 V, 40 VA control transformer and control provisions supplied for single or multi-stage add on cooling.
  • Built-in, high level self diagnostics with fault code displays standard on integrated control module for reliable operation.
  • Front-facing screws on flame sensor and hot surgace ignitor for ease of service.
  • Front-facing screws on blower assembly for easy access and removal of blower.
  • Constant torque blower motor for cooling SEER2 enhancement.
  • Blower-off delay for cooling SEER2 improvement.
  • Continuous fan options for indoor air quality (IAQ) performance.
  • Airflow leakage less than 2% of nominal airflow for duct performance testing conditions.
  • Low unit current requirement for easy replacement application.
  • Electronic hot surface ignition saves fuel cost with increased dependability and reliability.
  • 100% shut-off main gas valve for extra safety.
  • Inducer rotates for easy conversion of venting options.
  • The 26k model is not convertible for use with propane (LP) gas. All other models are fieldconvertible for use with propane (LP) gas with an optional propane accessory conversion kit.
  • Five-speed direct drive standard ECM blower motor.
  • Hi-tech tubular aluminized steel primary heat exchanger.
  • Corrosion resistant stainless steel secondary heat exchanger including rear cover pan and front vestibule panel.
  • Quiet inducer operation.
  • Timed on, adjustable off blower capability for maximum comfort.
  • Blower door safety switch below the blower deck.
  • Solid removable bottom panel allows easy conversion for bottom return air applications.
  • Twinning terminal for controlling two identical models installed with a common duct system. No external kit is required.
  • External air filters are used for maximum flexibility in meeting customers' IAQ needs.
  • 1/4 turn knobs are provided for easy independent door removal.
  • Insulated blower compartment for thermal and acoustic performance.
  • Internal condensate trap design (patent pending) provides condensate management options and is self priming to prevent nuisance problems.
  • Protection included from air intake, exhaust vent, or condensate blockage. Venting applications may be installed as either two-pipe sealed combustion or single-pipe vent (except 26k) using indoor combustion air.
  • No special vent termination required.
  • These condensing furnace models produce <40 ng/J NOx emissions.
  • Fold-up duct connector flanges for application flexibility.
  • Patented self-priming internal condensate trap design for easy installation.

    York RG19040A10MPS1

  • Item#:
    RG19060A10MPS1
    Manufacturer Item:
    RG19060A10MPS1
    Manufacturer:
    JC RESIDENTIAL AND LIGHT COMME
    Features
  • Easily applied in upflow, horizontal left or horizontal right, or downflow installation with minimal conversion necessary.
  • Venting kit for downflow (counter-flow) applications on B, C, and D cabinets where side discharge is not possible.
  • The unit cabinet is compact and easy to install with an ideal height of 33 in.
  • Full length fold-up duct connector flanges for application flexibility.
  • Easy access to controls to connect power and control wiring.
  • No electrical knockouts to deal with, making installation easier.
  • 24 V, 40 VA control transformer and control provisions supplied for single or multi-stage add on cooling or heat pump heating.
  • Built-in, high level self diagnostics with fault code displays standard on integrated control module for reliable operation.
  • Front-facing screws on flame sensor and hot surface ignitor for ease of service.
  • Front-facing screws on blower assembly for easy access and removal of blower.
  • Constant torque blower motor for cooling SEER2 enhancement.
  • Blower-off delay for cooling SEER2 improvement.
  • Continuous fan options for indoor air quality (IAQ) performance.
  • Airflow leakage less than 2% of nominal airflow for duct performance testing conditions.
  • Low unit current requirement for easy replacement application.
  • Electronic hot surface ignition saves fuel cost with increased dependability and reliability.
  • 100% shut-off main gas valve for extra safety.
  • Inducer rotates for easy conversion of venting options.
  • Five-speed direct drive standard ECM blower motor.
  • Hi-tech tubular aluminized steel primary heat exchanger.
  • Corrosion resistant stainless steel secondary heat exchanger including rear cover pan and front vestibule panel.
  • Quiet inducer operation.

    York RL18080C16MPS1

  • Item#:
    RL18100C16MPS1
    Manufacturer Item:
    RL18100C16MPS1
    Manufacturer:
    JC RESIDENTIAL AND LIGHT COMME
    Features
  • Easily applied in upflow, horizontal left or horizontal right, or downflow installation with minimal conversion necessary. Venting kit for downflow (counter-flow) applications on B, C, and D cabinets where side discharge is not possible.
  • The unit cabinet is compact and easy to install with an ideal height of 33 in.
  • Full length fold-up duct connector flanges for application flexibility.
  • Easy access to controls to connect power and control wiring.
  • No electrical knockouts to deal with, making installation easier.
  • 24 V, 40 VA control transformer and control provisions supplied for single or multi-stage add on cooling.
  • Built-in, high level self diagnostics with fault code displays standard on integrated control module for reliable operation.
  • Front-facing screws on flame sensor and hot surgace ignitor for ease of service.
  • Front-facing screws on blower assembly for easy access and removal of blower.
  • Constant torque blower motor for cooling SEER2 enhancement.
  • Blower-off delay for cooling SEER2 improvement.
  • Continuous fan options for indoor air quality (IAQ) performance.
  • Airflow leakage less than 2% of nominal airflow for duct performance testing conditions.
  • Low unit current requirement for easy replacement application.
  • Electronic hot surface ignition saves fuel cost with increased dependability and reliability.
  • 100% shut-off main gas valve for extra safety.
  • Inducer rotates for easy conversion of venting options.
  • The 26k model is not convertible for use with propane (LP) gas. All other models are fieldconvertible for use with propane (LP) gas with an optional propane accessory conversion kit.
  • Five-speed direct drive standard ECM blower motor.
  • Hi-tech tubular aluminized steel primary heat exchanger.
  • Corrosion resistant stainless steel secondary heat exchanger including rear cover pan and front vestibule panel.
  • Quiet inducer operation.
  • Timed on, adjustable off blower capability for maximum comfort.
  • Blower door safety switch below the blower deck.
  • Solid removable bottom panel allows easy conversion for bottom return air applications.
  • Twinning terminal for controlling two identical models installed with a common duct system. No external kit is required.
  • External air filters are used for maximum flexibility in meeting customers' IAQ needs.
  • 1/4 turn knobs are provided for easy independent door removal.
  • Insulated blower compartment for thermal and acoustic performance.
  • Internal condensate trap design (patent pending) provides condensate management options and is self priming to prevent nuisance problems.
  • Protection included from air intake, exhaust vent, or condensate blockage. Venting applications may be installed as either two-pipe sealed combustion or single-pipe vent (except 26k) using indoor combustion air.
  • No special vent termination required.
  • These condensing furnace models produce <40 ng/J NOx emissions.
  • Fold-up duct connector flanges for application flexibility.
  • Patented self-priming internal condensate trap design for easy installation.

    York RG19100C20MPS1

  • Item#:
    RG19120D20MPS1
    Manufacturer Item:
    RG19120D20MPS1
    Manufacturer:
    JC RESIDENTIAL AND LIGHT COMME
    Features
  • Easily applied in upflow, horizontal left or horizontal right, or downflow installation with minimal conversion necessary. Venting kit for downflow (counter-flow) applications on B, C, and D cabinets where side discharge is not possible.
  • The unit cabinet is compact and easy to install with an ideal height of 33 in.
  • Full length fold-up duct connector flanges for application flexibility.
  • Easy access to controls to connect power and control wiring.
  • No electrical knockouts to deal with, making installation easier.
  • 24 V, 40 VA control transformer and control provisions supplied for single or multi-stage add on cooling.
  • Built-in, high level self diagnostics with fault code displays standard on integrated control module for reliable operation.
  • Front-facing screws on flame sensor and hot surgace ignitor for ease of service.
  • Front-facing screws on blower assembly for easy access and removal of blower.
  • Constant torque blower motor for cooling SEER2 enhancement.
  • Blower-off delay for cooling SEER2 improvement.
  • Continuous fan options for indoor air quality (IAQ) performance.
  • Airflow leakage less than 2% of nominal airflow for duct performance testing conditions.
  • Low unit current requirement for easy replacement application.
  • Electronic hot surface ignition saves fuel cost with increased dependability and reliability.
  • 100% shut-off main gas valve for extra safety.
  • Inducer rotates for easy conversion of venting options.
  • The 26k model is not convertible for use with propane (LP) gas. All other models are fieldconvertible for use with propane (LP) gas with an optional propane accessory conversion kit.
  • Five-speed direct drive standard ECM blower motor.
  • Hi-tech tubular aluminized steel primary heat exchanger.
  • Corrosion resistant stainless steel secondary heat exchanger including rear cover pan and front vestibule panel.
  • Quiet inducer operation.
  • Timed on, adjustable off blower capability for maximum comfort.
  • Blower door safety switch below the blower deck.
  • Solid removable bottom panel allows easy conversion for bottom return air applications.
  • Twinning terminal for controlling two identical models installed with a common duct system. No external kit is required.
  • External air filters are used for maximum flexibility in meeting customers' IAQ needs.
  • 1/4 turn knobs are provided for easy independent door removal.
  • Insulated blower compartment for thermal and acoustic performance.
  • Internal condensate trap design (patent pending) provides condensate management options and is self priming to prevent nuisance problems.
  • Protection included from air intake, exhaust vent, or condensate blockage. Venting applications may be installed as either two-pipe sealed combustion or single-pipe vent (except 26k) using indoor combustion air.
  • No special vent termination required.
  • These condensing furnace models produce <40 ng/J NOx emissions.
  • Fold-up duct connector flanges for application flexibility.
  • Patented self-priming internal condensate trap design for easy installation.

    Thermo Pride GMD2-60N

  • Item#:
    RG19040A10MPS1
    Manufacturer Item:
    RG19040A10MPS1
    Manufacturer:
    JC RESIDENTIAL AND LIGHT COMME
    Features
  • Easily applied in upflow, horizontal left or horizontal right, or downflow installation with minimal conversion necessary. Venting kit for downflow (counter-flow) applications on B, C, and D cabinets where side discharge is not possible.
  • The unit cabinet is compact and easy to install with an ideal height of 33 in.
  • Full length fold-up duct connector flanges for application flexibility.
  • Easy access to controls to connect power and control wiring.
  • No electrical knockouts to deal with, making installation easier.
  • 24 V, 40 VA control transformer and control provisions supplied for single or multi-stage add on cooling.
  • Built-in, high level self diagnostics with fault code displays standard on integrated control module for reliable operation.
  • Front-facing screws on flame sensor and hot surgace ignitor for ease of service.
  • Front-facing screws on blower assembly for easy access and removal of blower.
  • Constant torque blower motor for cooling SEER2 enhancement.
  • Blower-off delay for cooling SEER2 improvement.
  • Continuous fan options for indoor air quality (IAQ) performance.
  • Airflow leakage less than 2% of nominal airflow for duct performance testing conditions.
  • Low unit current requirement for easy replacement application.
  • Electronic hot surface ignition saves fuel cost with increased dependability and reliability.
  • 100% shut-off main gas valve for extra safety.
  • Inducer rotates for easy conversion of venting options.
  • The 26k model is not convertible for use with propane (LP) gas. All other models are fieldconvertible for use with propane (LP) gas with an optional propane accessory conversion kit.
  • Five-speed direct drive standard ECM blower motor.
  • Hi-tech tubular aluminized steel primary heat exchanger.
  • Corrosion resistant stainless steel secondary heat exchanger including rear cover pan and front vestibule panel.
  • Quiet inducer operation.
  • Timed on, adjustable off blower capability for maximum comfort.
  • Blower door safety switch below the blower deck.
  • Solid removable bottom panel allows easy conversion for bottom return air applications.
  • Twinning terminal for controlling two identical models installed with a common duct system. No external kit is required.
  • External air filters are used for maximum flexibility in meeting customers' IAQ needs.
  • 1/4 turn knobs are provided for easy independent door removal.
  • Insulated blower compartment for thermal and acoustic performance.
  • Internal condensate trap design (patent pending) provides condensate management options and is self priming to prevent nuisance problems.
  • Protection included from air intake, exhaust vent, or condensate blockage. Venting applications may be installed as either two-pipe sealed combustion or single-pipe vent (except 26k) using indoor combustion air.
  • No special vent termination required.
  • These condensing furnace models produce <40 ng/J NOx emissions.
  • Fold-up duct connector flanges for application flexibility.
  • Patented self-priming internal condensate trap design for easy installation.

    York RG19060B12MPS1

  • Item#:
    RG19080B12MPS1
    Manufacturer Item:
    RG19080B12MPS1
    Manufacturer:
    JC RESIDENTIAL AND LIGHT COMME
    Features
  • Easily applied in upflow, horizontal left or horizontal right, or downflow installation with minimal conversion necessary.
  • Venting kit for downflow (counter-flow) applications on B, C, and D cabinets where side discharge is not possible.
  • The unit cabinet is compact and easy to install with an ideal height of 33 in.
  • Full length fold-up duct connector flanges for application flexibility.
  • Easy access to controls to connect power and control wiring.
  • No electrical knockouts to deal with, making installation easier.
  • 24 V, 40 VA control transformer and control provisions supplied for single or multi-stage add on cooling or heat pump heating.
  • Built-in, high level self diagnostics with fault code displays standard on integrated control module for reliable operation.
  • Front-facing screws on flame sensor and hot surface ignitor for ease of service.
  • Front-facing screws on blower assembly for easy access and removal of blower.
  • Constant torque blower motor for cooling SEER2 enhancement.
  • Blower-off delay for cooling SEER2 improvement.
  • Continuous fan options for indoor air quality (IAQ) performance.
  • Airflow leakage less than 2% of nominal airflow for duct performance testing conditions.
  • Low unit current requirement for easy replacement application.
  • Electronic hot surface ignition saves fuel cost with increased dependability and reliability.
  • 100% shut-off main gas valve for extra safety.
  • Inducer rotates for easy conversion of venting options.
  • Five-speed direct drive standard ECM blower motor.
  • Hi-tech tubular aluminized steel primary heat exchanger.
  • Corrosion resistant stainless steel secondary heat exchanger including rear cover pan and front vestibule panel.
  • Quiet inducer operation.

    York RG19120D20MPS1

  • Item#:
    RL18040A12MPS1
    Manufacturer Item:
    RL18040A12MPS1
    Manufacturer:
    JC RESIDENTIAL AND LIGHT COMME
    |◀ 25 - 36 of 43 ▶|
    View: