S2K Commerce - Products Dropdown
S2K Commerce - Shopping Cart
S2K Commerce - Order Entry
Parker OSE12C Expansion Valve 12 Ton 7/8" OD x 1-3/8 OD R404A,
Parker OE-50-ZX200
Item#:
OSE12C
Manufacturer Item:
124214
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
Parker JP-1222-000 Quadring Oil Control OL-60,
,
,
Parker JP-1222-000
Item#:
JP-1222-000
Manufacturer Item:
698003
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
Solenoid Coil 24 VDC
- 18 Watt
- 50/60 Hz.
- Junction Box
Parker E6S140-HP
- Junction Box
- 50/60 Hz.
Parker SCE-AA-VZ External Type SCE Expansion Valve Body 3/8" x 1/2" OD 1/4-1/2 Ton
SCE-AA-VZ
Item#:
SCE-AA-VZ
Manufacturer Item:
040406-15
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
Parker SVE-4-CP100 Expansion Valve 4 Ton 1/2" x 7/8",
,
,
Parker SVE-3-CP100
Item#:
SVE-4-CP100
Manufacturer Item:
129719
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
Parker Brass Charge W External Equalizer Type C Thermostatic Expansion Valve, 1/4" x 1/2" Flare, 1/2-1 ton, R-402A, R-404A, R-507, R-402B, R-502
- The Parker C-EC-SC Series balance ported thermostatic expansion valves have a brass bar stock body with flare or sweat connections, adjustable superheat, long lasting replaceable power element and accessible internal parts. Each valve is factory tested to ensure positive leak-free performance. The balance port design provides perfect pin and port alignment and prevents pressure drop across the valve from influencing valve operation.
- Also available is the Parker C Series Interchangeable valve. These C Valves are supplied in two components, the thermostatic element and the valve body. The interchangeable nature of this part of the C family makes it ideal for reducing inventory, while increasing valve options.
- Markets
- Air Conditioning
- Refrigeration Food Retail
- Transportation
- Industrial Food Storage units
- Features/Benefits:
- Balance port design provides perfect pin and port alignment and prevents pressure drop across the valve from influencing valve operation
- Thermostatic charges available to match system conditions
- Available with External equalizer and internal equalizer
- Design working pressure of 450 psi (31 bar)
- Applications:
- Systems with widely varying operating conditions
- Capacity ranges from 1/8 to 8 ton R-22
- Supermarket cases and rack systems, Food and Beverage units
- Air Conditioning Residential, Commercial, Chillers
- Transportation Units on Truck/Trailer, Bus and Vans
Parker SVE-4-CP100
- Transportation Units on Truck/Trailer, Bus and Vans
- Air Conditioning Residential, Commercial, Chillers
- Supermarket cases and rack systems, Food and Beverage units
- Capacity ranges from 1/8 to 8 ton R-22
- Systems with widely varying operating conditions
- Applications:
- Design working pressure of 450 psi (31 bar)
- Available with External equalizer and internal equalizer
- Thermostatic charges available to match system conditions
- Balance port design provides perfect pin and port alignment and prevents pressure drop across the valve from influencing valve operation
- Features/Benefits:
- Industrial Food Storage units
- Transportation
- Refrigeration Food Retail
- Air Conditioning
- Markets
- Also available is the Parker C Series Interchangeable valve. These C Valves are supplied in two components, the thermostatic element and the valve body. The interchangeable nature of this part of the C family makes it ideal for reducing inventory, while increasing valve options.
Item#:
CE-AA-SW
Manufacturer Item:
040334-01
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
Parker LAC head pressure control valves have a brass body with copper connections. These valves are nonadjustable. They perform the function of limiting flow of refrigerant from the condenser and at the same time regulate the flow of hot gas around the condenser to the receiver during low ambient conditions, so as to keep the refrigerant in the liquid line at proper pressure. Each valve is factory tested to ensure positive leak-free performance.
,
- 210 PSI
- 1/2" OD
,
Parker LAC-5-180-5/8OD
Item#:
LAC-5-210-1/2OD
Manufacturer Item:
903071P
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
Parker SVE-3-CP100 Expansion Valve 3 Ton R22 1/2" x 5/8/"
,
,
,
,
Parker SCE-C-3X4-ODF-BODY
Item#:
SVE-3-CP100
Manufacturer Item:
129642
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
Straight Through Electronic Regulator Valve #4 5/8" OD
- Bi-Polar Stepper Motor
- Tight Seating Piston Pesign
- Serviceable Construction
- Construction Brass & Coppper
- Actuator Design Provides Great Resolution
Parker SPORT-21-21
- Actuator Design Provides Great Resolution
- Construction Brass & Coppper
- Serviceable Construction
- Tight Seating Piston Pesign
Item#:
CDST-4-5-20FT-S
Manufacturer Item:
805598
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
Straight Through Electronic Regulator Valve #4 7/8" OD
- Bi-Polar Stepper Motor
- Tight Seating Piston Pesign
- Serviceable Construction
- Construction Brass & Coppper
- Actuator Design Provides Great Resolution
Henry Technologies 5240-450
- Actuator Design Provides Great Resolution
- Construction Brass & Coppper
- Serviceable Construction
- Tight Seating Piston Pesign
Item#:
CDST-4-7-20FT-S
Manufacturer Item:
805599
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
Straight Through Electronic Regulator Valve #7 1-3/8" OD
- Bi-Polar Stepper Motor
- Tight Seating Piston Pesign
- Serviceable Construction
- Construction Brass & Coppper
- Actuator Design Provides Great Resolution
Parker CDST-4-7-20FT-S
- Actuator Design Provides Great Resolution
- Construction Brass & Coppper
- Serviceable Construction
- Tight Seating Piston Pesign
Item#:
CDST-7-11-20FT-S
Manufacturer Item:
805618
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
The ORD valve is a pressure differential valve that
responds to changes in the pressure difference across the valve, Figure 6 on the next page. The valve designation stands for Opens on Rise of Differential pressure. Therefore, the ORD is dependent on some other control valve or action for its operation. And in this respect, it is used with the ORI for head pressure control. As the ORI valve starts to throttle the flow of liquid refrigerant from the condenser, a pressure differential is created across the ORD. When the differential reaches setpoint, the ORD starts to open and bypasses hot gas to the liquid drain line. As the differential increases, the ORD opens further until its full stroke is reached at a differential of 10 psi above setpoint. Due to its function in the control of head pressure, the full stroke can be utilized in selecting the ORD. The standard pressure setting for the ORD is 20 psig. For systems where the pressure drop between the compressor and the receiver is higher than 14 psi, an ORD with a higher setting is available.
- 20 PSI
- 5/8" OD
Parker LAC-5-210-1/2OD
- 5/8" OD
Item#:
ORD-4-20
Manufacturer Item:
902877
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
