Home  > PARKER HANNIFIN(AFTERMARKET)(x)
|◀ 133 - 144 of 264 ▶|
View:
Sporlan Power Element for SC(E), EC(E) and C(E) Series Thermostatic Expansion Valves 60" cap R12, R134A -40 to +60F
,
,

Item#:
KT-46-JX-60
Manufacturer Item:
KT-43-JCP60
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
Sporlan 180891P Power Element for R22/R407C/R417A Refrigerant 60" Capillary
Item#:
KT-83-VX100
Manufacturer Item:
KT-83-VCP100
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
Nu-Calgon 4217-W3 Self-Adhesive Insulation Tape, 3 feet Roll L x 2" W x 1/8" T, Cork, Black
Item#:
J6-3
Manufacturer Item:
4217-W3
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
Sporlan C Series Power Element for R404/R507/R402A/R408A/R502 Refrigerant 60" Capillary
Item#:
KT-46-SW
Manufacturer Item:
KT-43-SC
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
Parker LAC head pressure control valves have a brass body with copper connections. These valves are nonadjustable. They perform the function of limiting flow of refrigerant from the condenser and at the same time regulate the flow of hot gas around the condenser to the receiver during low ambient conditions, so as to keep the refrigerant in the liquid line at proper pressure. Each valve is factory tested to ensure positive leak-free performance.
    180 PSI
  • 1/2" OD
Item#:
LAC-4-180-1/2OD
Manufacturer Item:
903038P
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
Parker LAC head pressure control valves have a brass body with copper connections. These valves are nonadjustable. They perform the function of limiting flow of refrigerant from the condenser and at the same time regulate the flow of hot gas around the condenser to the receiver during low ambient conditions, so as to keep the refrigerant in the liquid line at proper pressure. Each valve is factory tested to ensure positive leak-free performance.
    100 PSI
  • 5/8" OD
Item#:
LAC-5-100-5/8OD
Manufacturer Item:
903050P
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
Parker LAC head pressure control valves have a brass body with copper connections. These valves are nonadjustable. They perform the function of limiting flow of refrigerant from the condenser and at the same time regulate the flow of hot gas around the condenser to the receiver during low ambient conditions, so as to keep the refrigerant in the liquid line at proper pressure. Each valve is factory tested to ensure positive leak-free performance.
    295 PSI
  • 1/2" OD
Item#:
LAC-4-295HP-1/2OD
Manufacturer Item:
903111P
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
Parker LAC head pressure control valves have a brass body with copper connections. These valves are nonadjustable. They perform the function of limiting flow of refrigerant from the condenser and at the same time regulate the flow of hot gas around the condenser to the receiver during low ambient conditions, so as to keep the refrigerant in the liquid line at proper pressure. Each valve is factory tested to ensure positive leak-free performance.
    180 PSI
  • 3/8" OD
Item#:
LAC-4-180-3/8OD
Manufacturer Item:
903024P
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
Parker LAC head pressure control valves have a brass body with copper connections. These valves are nonadjustable. They perform the function of limiting flow of refrigerant from the condenser and at the same time regulate the flow of hot gas around the condenser to the receiver during low ambient conditions, so as to keep the refrigerant in the liquid line at proper pressure. Each valve is factory tested to ensure positive leak-free performance.
    210 PSI
  • 3/8" OD
Item#:
LAC-4-210-3S
Manufacturer Item:
903005P
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
Parker LAC head pressure control valves have a brass body with copper connections. These valves are nonadjustable. They perform the function of limiting flow of refrigerant from the condenser and at the same time regulate the flow of hot gas around the condenser to the receiver during low ambient conditions, so as to keep the refrigerant in the liquid line at proper pressure. Each valve is factory tested to ensure positive leak-free performance.
    100 PSI
  • 3/8" OD
Item#:
LAC-4-100-3/8OD
Manufacturer Item:
903017P
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
Parker LAC head pressure control valves have a brass body with copper connections. These valves are nonadjustable. They perform the function of limiting flow of refrigerant from the condenser and at the same time regulate the flow of hot gas around the condenser to the receiver during low ambient conditions, so as to keep the refrigerant in the liquid line at proper pressure. Each valve is factory tested to ensure positi leak-free performance.
    180 PSI
  • 5/8" OD
Item#:
LAC-5-180-5/8OD
Manufacturer Item:
903029P
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
Parker Unsurpassed Moisture and Acid Capacities Maximum Filtration Capability for Today's Systems.
  • Compatible with Mineral Oil, Alkylbenzene and POE Lubricants Solid Molecular Sieve Core.
  • Made in the USA
  • Unsurpassed moisture capacity and maximum filtration capability for todays systems
  • Compatible with all commercially available refrigerants including R-410A
  • Compatible with mineral oil, alkylbenzene and POE lubricants
  • Solid molecular sieve core
  • Solid copper ODF solder fittings and nickel plated steel SAE fittings
  • Powder paint exterior coating surpasses 500 hour ASTM salt spray test to resist corrosion
  • Maximum Rated Pressure of 650 psig (44.8 bar)
  • UL Listed under SMGT/SMGT7-SA1756
  • UL Listed under SMGT/SMGT7-SA1756
  • Item#:
    LLD-414
    Manufacturer Item:
    450259-001
    Manufacturer:
    PARKER HANNIFIN(AFTERMARKET)
    |◀ 133 - 144 of 264 ▶|