ActionsParker Powder Painted Steel Gold Label Liquid Line Filter Drier
- 1/2" OD
- 8 Cube
- 10 Micron
- Solid copper connections
- Unsurpassed Moisture and Acid Capacities Maximum Filtration Capability for Today's Systems.
- Compatible with Mineral Oil, Alkylbenzene and POE Lubricants Solid Molecular Sieve Core.
- Made in the USA
- Unsurpassed moisture capacity and maximum filtration capability for todays systems
- Compatible with all commercially available refrigerants including R-410A
- Compatible with mineral oil, alkylbenzene and POE lubricants
- Solid molecular sieve core
- Solid copper ODF solder fittings and nickel plated steel SAE fittings
- Powder paint exterior coating surpasses 500 hour ASTM salt spray test to resist corrosion
- Maximum Rated Pressure of 650 psig (44.8 bar).
- UL Listed under SMGT/SMGT7-SA1756,
,
Item#:
033199-0849
Manufacturer Item:
HNH084S
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
Sanhua Powder Coated Liquid Line Filter Drier with Sight Glass, 3/8" OD
- High moisture and acid capacity
- Maximum filtration capacity
- Exceptional compatibility with new polyolester oil
- Spring loaded, molecular sieve and activated alumina
- Solid copper sweat fitting
- Powder paint exterior coating surpasses 500 hr ASTM salt spray test to resist corrosion
- Eliminates concern of additive stripping
- 16 Cube
DSG Series liquid line filter drier/sight glass combination is a liquid line filter drier with a sight glass connected to the outlet side of the filter drier are used in refrigeration system with unidirectional flow to absorb moisture in the system and to filter out the impurities. Observe property changes of the refrigerant (liquid / vapor) and indicate the moisture level by the sight glass as well,
,
Sanhua Powder Coated Liquid Line Filter Drier with Sight Glass, 3/8" OD
- High moisture and acid capacity
- Maximum filtration capacity
- Exceptional compatibility with new polyolester oil
- Spring loaded, molecular sieve and activated alumina
- Solid copper sweat fitting
- Powder paint exterior coating surpasses 500 hr ASTM salt spray test to resist corrosion
- Eliminates concern of additive stripping
- 8 Cube
DSG Series liquid line filter drier/sight glass combination is a liquid line filter drier with a sight glass connected to the outlet side of the filter drier are used in refrigeration system with unidirectional flow to absorb moisture in the system and to filter out the impurities. Observe property changes of the refrigerant (liquid / vapor) and indicate the moisture level by the sight glass as well ,
,
The Parker Virginia line of chemicals offers exceptional cleaning effectiveness for condenser coils, evaporator coils, ice machines, and commercial dishwashers. Accumulated dirt, dust and grease insulate against heat transfer which can reduce system BTU capacity by as much as 30%. This results in increased compressor amperage draw and longer unit run times which causes increased utility costs and decreased equipment service life. Keeping heat transfer coils clean ensures maximum performance and efficiency. Suniso premium naphthenic based refrigeration and A/C oils have been the AC/R industry standard for over 40 years because of the long trouble-free service records of systems that have used Suniso refrigeration oils.
,
- Low floc point, low wax content minimizes the potential for wax separation when used in low temperature applications
- Low pour point prevents oil from congealing in refrigerant lines
- Freedom from moisture and other contaminants prevents premature wear and the plugging of lines and oil ports
- Controlled viscosity, maintains high film strength even when diluted with refrigerant, yet remains fluid under extreme low temperature operating conditions
- High dielectric strength allows the oil/refrigerant mixture to serve as an insulator between the motor windings and the body in a compressor
- High chemical stability minimizes the reaction with refrigerants and other materials that are a part of the system
- High performance desiccant package provides high water and acid capacity
- Complete contaminant control to protect and extend system life and ensure system reliability
- Porous molded core provides excellent filtration of solid debris for TEV and compressor protection
- Less than 0.01 mm Hg vapor pressure
- Solubility: insoluble in water
- Partition coefficient: n-octanol/water or Coefficient of water/oil distribution: greater than 20
,
Item#:
F49-5
Manufacturer Item:
475330
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
Parker Sight Glass Moisture Indicator
The Parker PSG Moisture and Liquid Indicator combines the two functions of moisture and liquid indication into a single economical product. It takes the guess work out of servicing refrigeration and air conditioning equipment. The PSG assists the technician in determining the state of the circulating refrigerant at a particular location and if a safe moisture level exists in the system. Excessive moisture in refrigerant systems can cause unwanted chemistries such as hydrolysis of lubricants and other materials, corrosion of metals, copper plating, ice formation at the metering device and a chemical change in the motor insulation of a hermetic compressor.,
,
The Parker PSG Moisture and Liquid Indicator combines the two functions of moisture and liquid indication into a single economical product. It takes the guess work out of servicing refrigeration and air conditioning equipment. The PSG assists the technician in determining the state of the circulating refrigerant at a particular location and if a safe moisture level exists in the system. Excessive moisture in refrigerant systems can cause unwanted chemistries such as hydrolysis of lubricants and other materials, corrosion of metals, copper plating, ice formation at the metering device and a chemical change in the motor insulation of a hermetic compressor.,
,
Item#:
PSG-4MF
Manufacturer Item:
700262-002
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
Parker Sight Glass Moisture Indicator
The Parker PSG Moisture and Liquid Indicator combines the two functions of moisture and liquid indication into a single economical product. It takes the guess work out of servicing refrigeration and air conditioning equipment. The PSG assists the technician in determining the state of the circulating refrigerant at a particular location and if a safe moisture level exists in the system. Excessive moisture in refrigerant systems can cause unwanted chemistries such as hydrolysis of lubricants and other materials, corrosion of metals, copper plating, ice formation at the metering device and a chemical change in the motor insulation of a hermetic compressor.,
,
The Parker PSG Moisture and Liquid Indicator combines the two functions of moisture and liquid indication into a single economical product. It takes the guess work out of servicing refrigeration and air conditioning equipment. The PSG assists the technician in determining the state of the circulating refrigerant at a particular location and if a safe moisture level exists in the system. Excessive moisture in refrigerant systems can cause unwanted chemistries such as hydrolysis of lubricants and other materials, corrosion of metals, copper plating, ice formation at the metering device and a chemical change in the motor insulation of a hermetic compressor.,
,
Parker PSG-4S
Item#:
PSG-4S
Manufacturer Item:
700301-002
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
Parker Sight Glass Moisture Indicator
The Parker PSG Moisture and Liquid Indicator combines the two functions of moisture and liquid indication into a single economical product. It takes the guess work out of servicing refrigeration and air conditioning equipment. The PSG assists the technician in determining the state of the circulating refrigerant at a particular location and if a safe moisture level exists in the system. Excessive moisture in refrigerant systems can cause unwanted chemistries such as hydrolysis of lubricants and other materials, corrosion of metals, copper plating, ice formation at the metering device and a chemical change in the motor insulation of a hermetic compressor.,
,
The Parker PSG Moisture and Liquid Indicator combines the two functions of moisture and liquid indication into a single economical product. It takes the guess work out of servicing refrigeration and air conditioning equipment. The PSG assists the technician in determining the state of the circulating refrigerant at a particular location and if a safe moisture level exists in the system. Excessive moisture in refrigerant systems can cause unwanted chemistries such as hydrolysis of lubricants and other materials, corrosion of metals, copper plating, ice formation at the metering device and a chemical change in the motor insulation of a hermetic compressor.,
,
Item#:
PSG-2S
Manufacturer Item:
700055-001
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
Parker Sight Glass Moisture Indicator
The Parker PSG Moisture and Liquid Indicator combines the two functions of moisture and liquid indication into a single economical product. It takes the guess work out of servicing refrigeration and air conditioning equipment. The PSG assists the technician in determining the state of the circulating refrigerant at a particular location and if a safe moisture level exists in the system. Excessive moisture in refrigerant systems can cause unwanted chemistries such as hydrolysis of lubricants and other materials, corrosion of metals, copper plating, ice formation at the metering device and a chemical change in the motor insulation of a hermetic compressor.,
The Parker PSG Moisture and Liquid Indicator combines the two functions of moisture and liquid indication into a single economical product. It takes the guess work out of servicing refrigeration and air conditioning equipment. The PSG assists the technician in determining the state of the circulating refrigerant at a particular location and if a safe moisture level exists in the system. Excessive moisture in refrigerant systems can cause unwanted chemistries such as hydrolysis of lubricants and other materials, corrosion of metals, copper plating, ice formation at the metering device and a chemical change in the motor insulation of a hermetic compressor.,
Parker PSG-3MF
Item#:
PSG-3MF
Manufacturer Item:
SA-13FM
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
Parker Sight Glass Moisture Indicator
The Parker PSG Moisture and Liquid Indicator combines the two functions of moisture and liquid indication into a single economical product. It takes the guess work out of servicing refrigeration and air conditioning equipment. The PSG assists the technician in determining the state of the circulating refrigerant at a particular location and if a safe moisture level exists in the system. Excessive moisture in refrigerant systems can cause unwanted chemistries such as hydrolysis of lubricants and other materials, corrosion of metals, copper plating, ice formation at the metering device and a chemical change in the motor insulation of a hermetic compressor.,
,
The Parker PSG Moisture and Liquid Indicator combines the two functions of moisture and liquid indication into a single economical product. It takes the guess work out of servicing refrigeration and air conditioning equipment. The PSG assists the technician in determining the state of the circulating refrigerant at a particular location and if a safe moisture level exists in the system. Excessive moisture in refrigerant systems can cause unwanted chemistries such as hydrolysis of lubricants and other materials, corrosion of metals, copper plating, ice formation at the metering device and a chemical change in the motor insulation of a hermetic compressor.,
,
Parker PSG-3S
Item#:
PSG-3S
Manufacturer Item:
SA-13S
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
Parker Sight Glass Moisture Indicator
The Parker PSG Moisture and Liquid Indicator combines the two functions of moisture and liquid indication into a single economical product. It takes the guess work out of servicing refrigeration and air conditioning equipment. The PSG assists the technician in determining the state of the circulating refrigerant at a particular location and if a safe moisture level exists in the system. Excessive moisture in refrigerant systems can cause unwanted chemistries such as hydrolysis of lubricants and other materials, corrosion of metals, copper plating, ice formation at the metering device and a chemical change in the motor insulation of a hermetic compressor.,
,
The Parker PSG Moisture and Liquid Indicator combines the two functions of moisture and liquid indication into a single economical product. It takes the guess work out of servicing refrigeration and air conditioning equipment. The PSG assists the technician in determining the state of the circulating refrigerant at a particular location and if a safe moisture level exists in the system. Excessive moisture in refrigerant systems can cause unwanted chemistries such as hydrolysis of lubricants and other materials, corrosion of metals, copper plating, ice formation at the metering device and a chemical change in the motor insulation of a hermetic compressor.,
,
Item#:
PSG-5S
Manufacturer Item:
700418-002
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
Parker Sight Glass Moisture Indicator
The Parker PSG Moisture and Liquid Indicator combines the two functions of moisture and liquid indication into a single economical product. It takes the guess work out of servicing refrigeration and air conditioning equipment. The PSG assists the technician in determining the state of the circulating refrigerant at a particular location and if a safe moisture level exists in the system. Excessive moisture in refrigerant systems can cause unwanted chemistries such as hydrolysis of lubricants and other materials, corrosion of metals, copper plating, ice formation at the metering device and a chemical change in the motor insulation of a hermetic compressor.,
,
The Parker PSG Moisture and Liquid Indicator combines the two functions of moisture and liquid indication into a single economical product. It takes the guess work out of servicing refrigeration and air conditioning equipment. The PSG assists the technician in determining the state of the circulating refrigerant at a particular location and if a safe moisture level exists in the system. Excessive moisture in refrigerant systems can cause unwanted chemistries such as hydrolysis of lubricants and other materials, corrosion of metals, copper plating, ice formation at the metering device and a chemical change in the motor insulation of a hermetic compressor.,
,
Item#: