Watts 111L Brass Poppet Pressure Relief Valve, 1/2", MNPT x FNPT, 125 psi
Watts Water 111L
Item#:
111L
Manufacturer Item:
111L
Manufacturer:
WATTS REGULATOR CO
Watts Regulators series 174A boiler pressure relief valves are used in hot water heating and domestic supply boiler applications to protect against excessive pressures on all types of hot water heating supply boiler equipment. It consists of a bronze body construction with NPT threaded female inlet and NPT threaded female outlet (drain) connections, non-metallic disc-to-metal seating, stainless steel spring, and test lever. Series 174A resists corrosive water conditions, sticking and freezing, and prevents water and sediment from being trapped in the seat. It is designed for emergency safety relief and shall not be used as an operating control.
- Safety relief valves for pressure protection only of all types of hot water heating boiler equipment
- Seat located above drain, water can't be trapped and sediment can't foul seat
- Non-mechanical seat-to-disc alignment will not stick or freeze
- Water seal of high temperature resisting material isolates spring working parts from water during relief
Watts Water 1156F-P
Watts Regulators series 174A boiler pressure relief valves are used in hot water heating and domestic supply boiler applications to protect against excessive pressures on all types of hot water heating supply boiler equipment. It consists of a bronze body construction with NPT threaded female inlet and NPT threaded female outlet drain connections, non-metallic disc-to-metal seating, stainless steel spring, and test lever. Series 174A resists corrosive water conditions, sticking and freezing and prevents water and sediment from being trapped in the seat. It is designed for emergency safety relief and shall not be used as an operating control.
,
,
- Safety relief valves for pressure protection only of all types of hot water heating boiler equipment
- Seat located above drain, water can't be trapped and sediment can't foul seat
- Non-mechanical seat-to-disc alignment will not stick or freeze
- Each hot water space heating boiler shall be equipped with a pressure relief valve set to relieve below the maximum boiler working pressure
- Water seal of high temperature resisting material isolates spring working parts from water during relief
,
,
Watts Water 174A-1-150
Item#:
174A-1-30
Manufacturer Item:
0274934
Manufacturer:
WATTS REGULATOR CO
Watts Regulators series 174A boiler pressure relief valves are used in hot water heating and domestic supply boiler applications to protect against excessive pressures on all types of hot water heating supply boiler equipment. It consists of a bronze body construction with NPT threaded female inlet and NPT threaded female outlet (drain) connections, non-metallic disc-to-metal seating, stainless steel spring, and test lever. Series 174A resists corrosive water conditions, sticking and freezing, and prevents water and sediment from being trapped in the seat. It is designed for emergency safety relief and shall not be used as an operating control.
,
- Safety relief valves for pressure protection only of all types of hot water heating boiler equipment
- Seat located above drain, water cant be trapped and sediment cant foul seat
- Non-mechanical seat-to-disc alignment will not stick or freeze
- Water seal of high temperature resisting material isolates spring working parts from water during relief
,
Watts Water 174A-3/4-40PSI
Item#:
174A-3/4-50
Manufacturer Item:
0274513
Manufacturer:
WATTS REGULATOR CO
Watts Regulators series 174A boiler pressure relief valves are used in hot water heating and domestic supply boiler applications to protect against excessive pressures on all types of hot water heating supply boiler equipment. It consists of a bronze body construction with NPT threaded female inlet and NPT threaded female outlet (drain) connections, non-metallic disc-to-metal seating, stainless steel spring, and test lever. Series 174A resists corrosive water conditions, sticking and freezing, and prevents water and sediment from being trapped in the seat. It is designed for emergency safety relief and shall not be used as an operating control.
,
- Safety relief valves for pressure protection only of all types of hot water heating boiler equipment
- Seat located above drain, water can't be trapped and sediment can't foul seat
- Non-mechanical seat-to-disc alignment will not stick or freeze
- Water seal of high temperature resisting material isolates spring working parts from water during relief
,
Watts Water 174A-1-50
Item#:
174A-3/4-125
Manufacturer Item:
0274751
Manufacturer:
WATTS REGULATOR CO
Watts Regulators series 174A boiler pressure relief valves are used in hot water heating and domestic supply boiler applications to protect against excessive pressures on all types of hot water heating supply boiler equipment. It consists of a bronze body construction with NPT threaded female inlet and NPT threaded female outlet (drain) connections, non-metallic disc-to-metal seating, stainless steel spring, and test lever. Series 174A resists corrosive water conditions, sticking and freezing, and prevents water and sediment from being trapped in the seat. It is designed for emergency safety relief and shall not be used as an operating control.
,
- Safety relief valves for pressure protection only of all types of hot water heating boiler equipment
- Seat located above drain, water cant be trapped and sediment cant foul seat
- Non-mechanical seat-to-disc alignment will not stick or freeze
- Water seal of high temperature resisting material isolates spring working parts from water during relief
,
Watts Water 174A-3/4-150
Item#:
174A-3/4-40PSI
Manufacturer Item:
0274479
Manufacturer:
WATTS REGULATOR CO
Watts Regulators series LF288A lead free hot or cold water anti-siphon VAC uum breakers prevent the reverse flow of polluted water from entering into the potable water supply due to backsiphonage. It consists of lead free brass body construction (LF288A) or chrome finish (LF288AC), chemical resistant silicone seat disc and an atmospheric vent to prevent spilling. Series LF288A has a full size orifice to assure pipe size capacity and maximum flow. It is ideal for low flow, non-continuous hot or cold water health hazard installations such as on laboratory equipment.
,
- Full size orifice for maximum flow
- Light weight disc assembly prevents spilling under all rates of flow
,
Watts Water 174A-3/4-75
Features
Seat located above drain so that water is never trapped and
sediment never fouls the seat
Nonmechanical seat-to-disc alignment that does not stick
or freeze
Water seal of high temperature resisting material to isolate
spring working
parts from water during relief*
Nonmetallic disc-to-metal seating
Available in diameters from 34" to 2"
Optional SentryPlus Alert discharge line flood sensor which
when paired with a connection kit (sold separately) can detect
excessive water discharges from the relief valve (Refer to
ES-FS-ReliefValve.)
Watts Water 288A1/2
Watts Regulators series 40L, 40xL automatic reseating temperature and pressure relief valves are used in commercial water heater applications to provide automatic temperature and pressure protection to hot water supply tanks and hot water heaters. They feature a bronze body with NPT male inlet and NPT female outlet connections, unique thermostat with special thermo-bonded coating, tamper-resistant bonnet screws, automatic reseating feature, and test lever. Model 40L has a short thermostat for installation directly in available tank tapings. Model 40xL has an extension thermostat for installation in the hot water outlet within the allowable distance from the top of the tank. Series 40L, 40xL valves are ASME rated and CSA listed.
,
- The combined 2-in-1 temperature and pressure relief valve provides the least expensive and proven means for protection against both excessive temperature and pressure emergency conditions
- Fully automatic temperature and pressure relief protection for domestic hot water supply tanks and heaters
- Includes test lever and extension thermostat for installation in hot water outlet within the allowable distance from the top of the tank
- Non-mechanical seat-to-disc alignment
- Thermostat is accurate and proven and exclusively designed and manufactured by watts
- Tamper-resistant bonnet screws
,
Watts Water 374A-3/4
Item#:
40XL-1-150
Manufacturer Item:
0163725
Manufacturer:
WATTS REGULATOR CO
Watts Regulators series 40L, 40xL automatic reseating temperature and pressure relief valves are used in commercial water heater applications to provide automatic temperature and pressure protection to hot water supply tanks and hot water heaters. They feature a bronze body with NPT male inlet and NPT female outlet connections, unique thermostat with special thermo-bonded coating, tamper-resistant bonnet screws, automatic reseating feature, and test lever. Model 40L has a short thermostat for installation directly in available tank tapings. Model 40xL has an extension thermostat for installation in the hot water outlet within the allowable distance from the top of the tank. Series 40L, 40xL valves are ASME rated and CSA listed.
- The combined 2-in-1 temperature and pressure relief valve provides the least expensive and proven means for protection against both excessive temperature and pressure emergency conditions
- Fully automatic temperature and pressure relief protection for domestic hot water supply tanks and heaters
- Includes test lever and extension thermostat for installation in hot water outlet within the allowable distance from the top of the tank
- Non-mechanical seat-to-disc alignment
- Thermostat is accurate and proven and exclusively designed and manufactured by watts
- Tamper-resistant bonnet screws
Watts Water 40XL-1-150
Item#:
40XL-150/210-FS-3/4
Manufacturer Item:
F158774
Manufacturer:
WATTS REGULATOR CO