ActionsTaco Zone Sentry® zone valve enhances the overall performance of any zone valve system. The unique patented technology in the Zone Sentry® utilizes a microcircuit based logic to control a gear driven electronic actuator which drives a ball valve based body design. All this adds up to a zone valve that leads the industry in energy efficiency, flow capacity (Cv), shutoff pressure rating, ease of installation, diagnostic capability and the number of valves (12) that can be use on a standard 40 VA transformer.
Taco Z100C
Tacos new shut-off Swivel-Flange® combines a full-port, ball valve and companion flange to isolate system circulators for easy removal and service, without draining the system. Simplify your next 00® circulator installation while saving material and labor costs. Solid brass uni-body construction, available in 1/2 - 1-1/2" NPT or sweat connections. The Swivel-Flange provides easier installation and positioning of the pump and lever handle in the most convenient location.
,
- Is a combination full port shut-off ball valve and swivel companion flange
- Easy 1/4-turn open/close operation
- Positive shut-off, leak free design
- Swivel flange allows 360 deg rotation
- High quality teflon seats
- Full port ball valve for unrestricted flow
- The simple quarter turn, lever handle operation allows for easy isolation, removal and service of circulators without draining the system
- Each flange set includes bolts and nuts
- Epoxy powder coated steel flange
,
SF-125T
Taco SFL100T Lead Free Solid Brass Shut-Off Ball Valve and Swivel-Flange Set 1" NPT,
,
,
SFL100T
Taco SFL-075T Lead Free Solid Brass Shut-Off Ball Valve and Swivel-Flange Set 3/4" NPT,
,
,
SFL-075T
Taco SR504-4 switching relay is the best choice for all your zoning needs, with advanced powerport cards, external diagnostic lights, switchable priority and contractor friendly PC board layouts. Combined with the time proven reliability of the 00 family of circulators and thermostats, total system integrating is achieved. External indicator lights provide instant diagnostic feedback, making a snap of service calls or new installation start-ups.
,
- External indicator lights
- Switchable priority
- Priority protection
- Simplified wiring
- Sealed relays
- Fuse protected outputs
- Compact design
- 100% factory tested
- Isolated end switch
- Contractor friendly PC board layout
- Universal thermostat compatibility
- All circulator relay connections, including ZC/ZR, are rated 1/3 HP (6 amp full load, 36 amp locked rotor) at 120 VAC
- End switch connections are rated 24 VAC, 1 amp
- All thermostat connections supply a 24 VAC class 2 output
,
Taco SR504
Taco SR504-ExP-1 Formed Sheet Metal 4-Zone Switching Relay with Priority, 24 volt Power Input or Output Terminal, 120 VAC Transformer Input, DPDT
,
- External indicator lights
- Switchable priority
- Simplified wiring
- Fully enclosed snap-out relays
- Compact design
- Fuse protected
- 100% factory tested
- Isolated end switch
- Contractor friendly PC board layout
- Universal thermostat compatibility
- Plug-in power port card slots
- Add-on power control plug
- Interface with ExP zone valve controls
- Extended 3 years warranty
- (3) power port slots, (1) power control plugs
,
Taco SR504EXP
Taco 569 Class 2 Transformer, 40 VA, 120 VAC Primary, 24 volt Secondary
,
- For reducing line voltage to low voltage when used in conjunction with Taco zone valves
- Terminal screws for secondary connections
- 4 x 4" plate mount
,
Taco 569
Item#:
569
Manufacturer Item:
569
Manufacturer:
TACO INC.
Taco ZVCXFR001RP Transformer ZVC 40 VA
ZVCXFR001RP
Item#:
ZVCXFR001RP
Manufacturer Item:
ZVCXFR-001RP
Manufacturer:
TACO INC.
Taco Flo-Checks prevent gravity circulation in forced hot water heating systems during periods when the boiler is hot, but the space heating zone is not wanted. This makes it possible to use the heating boiler to maintain domestic hot water year-round. You can also use Flo-Checks in systems with multiple circulator zones to allow heat to flow only into the zones that are calling for heat. In addition, the thumb screw can be opened manually for gravity feed applications, if the main circulator stops operating.
,
- In systems with multiple circulator zones to allow heat to flow only into the zones that are calling for heat
- Feature a thumb screw to manually open the valve and are available in a cast iron universal body and a bronze sweat in-line configuration
- The thumb screw can be opened manually for gravity feed applications, if the main circulator stops operating
- Open automatically when the circulator starts running, when the room thermostat is satisfied and the circulator is stopped, the flo-checks close immediately, preventing gravity circulation
- Water or glycol media
,
Taco B146-22
Item#:
B146-22
Manufacturer Item:
221-6
Manufacturer:
TACO INC.
Taco Flo-Checks prevent gravity circulation in forced hot water heating systems during periods when the boiler is hot, but the space heating zone is not wanted. This makes it possible to use the heating boiler to maintain domestic hot water year-round. You can also use Flo-Checks in systems with multiple circulator zones to allow heat to flow only into the zones that are calling for heat. In addition, the thumb screw can be opened manually for gravity feed applications, if the main circulator stops operating.
,
- In systems with multiple circulator zones to allow heat to flow only into the zones that are calling for heat
- Feature a thumb screw to manually open the valve and are available in a cast iron universal body and a bronze sweat in-line configuration
- The thumb screw can be opened manually for gravity feed applications, if the main circulator stops operating
- Open automatically when the circulator starts running, when the room thermostat is satisfied and the circulator is stopped, the flo-checks close immediately, preventing gravity circulation
- Water or glycol media
,
Taco B146-21
Item#:
B146-21
Manufacturer Item:
220-6
Manufacturer:
TACO INC.
Taco flo-cheks have dependably stopped gravity circulation in forced hot water heating systems for over 40 years. Flo-cheks open automatically when the circulator starts running. They feature a thumb screw to manually open the valve and are available in a cast iron universal body and a bronze sweat in-line configuration.
,
- Flo-cheks allow heat to flow only into the zones that are calling for heat
- Thumb screw can be manually opened for gravity feed applications if the main circulator stops operating
- Taco flo-cheks open automatically when the circulator starts running
,
Taco B146-20
Item#:
B146-20
Manufacturer Item:
218-3
Manufacturer:
TACO INC.
Taco flo-cheks have dependably stopped gravity circulation in forced hot water heating systems for over 40 years. Flo-cheks open automatically when the circulator starts running. They feature a thumb screw to manually open the valve and are available in a cast iron universal body and a bronze sweat in-line configuration.
,
- Flo-cheks allow heat to flow only into the zones that are calling for heat
- Thumb screw can be manually opened for gravity feed applications if the main circulator stops operating
- Taco flo-cheks open automatically when the circulator starts running
,
Taco B146-19
Item#:
B146-19
Manufacturer Item:
219-4
Manufacturer:
TACO INC.