S2K Commerce - Products Dropdown
S2K Commerce - Shopping Cart
S2K Commerce - Order Entry
Sid Harvey R215-75R Solid State Purple Peeper Ultraviolet Flame Detector, Solid state electronic flame detectors for use with Honeywell flame safeguard controls and amplifiers. Sense ultraviolet radiation produced by the combustion of gas, oil, coal or other fuels.,
,
,
Sid Harvey Remanufactured R210-10R
Item#:
R216-18R
Manufacturer Item:
R7249A1003
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey 3001157 Primary Control Box for F3/F5/F10/M3/M5/M10 Riello Burner, 110 VAC at 60 Hz
,
,
Sid Harvey Remanufactured R75-61R
Item#:
R78-10R
Manufacturer Item:
3001157
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured R520-52R Switching Relay 1-Zone 120 VAC 5 Amps REMANUFACTURED,
,
,
Sid Harvey Remanufactured R520-32R
Item#:
R520-52R
Manufacturer Item:
R520-52R
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Honeywell Protectorelay RA117A Universal Relay, 120 VAC , 75 sec Nominal
,
- Interrupted ignition type
- Combine a Protectorelar unit for cycling the burner and a Pyrostat flame detector for sensing temperature changes of flue gases up to 1000 deg F
- Manual reset of safety switch required after ignition failure completely shuts off main burner
- Include manual trip safety switch to assure burner shutdown during servicing
- Mount with flange for mounting on curved or flat surfaces
- Works with 2-wire and 3-wire 24 VAC thermostat
- 2 years warranty
,
Sid Harvey Remanufactured P9-22R
Item#:
R22R
Manufacturer Item:
RA117A
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Honeywell R8184G4074 Non-Recycle Oil Burner Control with Safety Timing, 120/220/240 VAC
,
- Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat
- Solid state flame sensing circuit
- LED on terminal strip indicates system lockout
Remote lockout indication - Enclosed safety switch with External reset butTon
- Manual trip lever opens safety switch for system maintenance
- Mounts on standard 4 x 4" junction box
- C554A cadmium sulfide flame detector and 24 VAC thermostat required
- With 30 sec safety timing, alarm outputs and manual safety switch
,
Sid Harvey Remanufactured R75-41R
Sid Harvey White Rodgers Cooling Controls 668-401 Gray Metal Enclosure Kwik-Sensor CAD Cell Relay, 120 VAC, 45 sec
- Intermittent ignition kwik-sensor CAD cell relays on oil burner systems with 15, 30 or 45 sec safety timing
- Certain types have unique signal-light feature with glows whenever safety lock-out occurs
- Line voltage safety switch eliminates burner run-on in the event that the motor relay contacts weld closed
- Solid state flame detection circuitry is not affected by vibration or high or low ambient temperatures
- Recycles on momentary flame failure or power interruption
- 4 x 4 Inch junction box, 10 Inch leads mounting
- 2 wire thermostat
- 0.4 amp thermostat anticipator setting
- Safety lock-out lamp White Rodgers Cooling Controls 668-401 Gray Metal Enclosure Kwik-Sensor CAD Cell Relay, 120 VAC, 45 secSid Harvey Item #:R79-6R: Replaces Part #:'s : R79-6,
,
Sid Harvey Remanufactured R78-10R
Item#:
R79-6R
Manufacturer Item:
668-401
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured R75-41R Oil Burner Primary Control R8184G Plastic Box 15 Second REMANUFACTURED,
,
,
Sid Harvey Remanufactured R75-40R
Item#:
R75-41R
Manufacturer Item:
R75-41R
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Honeywell RA832A1066 Switching Relay with Internal Transformer, 120 volt Input, 24 VAC Coil at 50/60 Hz, 0.4 amp Coil, DPST
- Provide intermediate switching of a line voltage device from a low voltage controller
- Integral transformer provides low voltage power for control circuit
- Includes enclosure
- Contact rating: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC full load; 44.4 amp at 120 VAC, 22.2 amp at 240 VAC locked rotor; 10 amp at 120 VAC, 6 amp at 240 VAC resistive; 2000 VA (120 - 240 VAC); secondary DC - 1 amp at 12 VDC, secondary millivolt - 300 milli-amp at 750 mV Honeywell RA832A1066 Switching Relay with Internal Transformer, 120 volt Input, 24 VAC Coil at 50/60 Hz, 0.4 amp Coil, DPSTSid Harvey Item #:R520-26R: Replaces Part #:'s : R520-26,
,
Sid Harvey Remanufactured R510-15R
Item#:
R520-26R
Manufacturer Item:
RA832A1066
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured R75-50R Oil Burner Control Genesis Control 7505A1000 REMANUFACTURED,
,
,
Sid Harvey Remanufactured R75-42R
Item#:
R75-50R
Manufacturer Item:
R75-50R
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured R75-52R Oil Burner Control Genesis Control 7505P1515 REMANUFACTURED,
,
,
Sid Harvey Remanufactured R75-51R
Item#:
R75-52R
Manufacturer Item:
R75-52R
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Honeywell R8184G4009 Non-Recycle Oil Burner Control with Safety Timing, 120/220/240 VAC
,
- Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat
- Solid state flame sensing circuit
- LED on terminal strip indicates system lockout
- Remote lockout indication
- Enclosed safety switch with External reset butTon
- Manual trip lever opens safety switch for system maintenance
- Mounts on standard 4 x 4" junction box
- C554A cadmium sulfide flame detector and 24 VAC thermostat required
- With 15 sec safety timing, alarm outputs and manual safety switch
,
Sid Harvey Remanufactured R75-29R
Item#:
R75-40R
Manufacturer Item:
R8184G4009
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured R75-51R Oil Burner Control Genesis Control 7505B1500 REMANUFACTURED,
,
,
Sid Harvey Remanufactured R75-50R
Item#:
R75-51R
Manufacturer Item:
R75-51R
Manufacturer:
SID HARVEY REMANUFACTURED
