White Rodgers Cooling Controls 50M56U-801Integrated HIS Furnace Control Board
  • System diagnostic LED with fault recall
  • Fused to protect low voltage system transformers
  • 3 fan speeds
  • Adapter harness for application flexibility
  • 15 sec pre-purge time
  • 30/45 heat delay for to fan on, 60/90/120/180 heat delay for to fan off, 2 cool delay for to fan on, 2/60 cool delay for to fan off, default setting
  • 5 sec post-purge
  • 0.8 sec max flame failure response time
  • 2 sec flame failure response time
  • 1.5 amp at 25 VAC 50/60 Hz for valve relay, 1.2 amp at 120 VAC 50/60 Hz for ignitor relay
  • Surface mount standoffs
  • 5 - 93% RH, non-condensing humidity
Sid Harvey Item #:50M56U-801: Replaces Part #:'s : ICM282 | ICM282A |,


White Rodgers 50M56U-751

Item#:
50M56U-801
Manufacturer Item:
50M56U-801
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 50M56U-843 1-Stage HSI Integrated Furnace Control Kit, 25 VAC, 0.45 amp, 5-1/4" W x 7" H x 1-1/4" D

White Rodgers 50M56U-801

Item#:
50M56U-843
Manufacturer Item:
50M56U-843
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 50A55-743 Replacement Integrated Furnace Control, 25 VAC, 0.45 amp, Import The 50A55-743 is an automatic gas interrupted ignition control that employs a microprocessor to continually monitor, analyze, and control the proper operation of the gas burner, inducer, and fan. signals interpreted during continual surveillance of the thermostat and flame sensing element initiate automatic ignition of the burner, sensing of the flame, and system shutoff during normal operation. these controls incorporate system fault analysis for quick gas flow shutoff , coupled with automatic ignition retry upon sensing a fault correction. it is designed as a replacement for the following controls.
  • Twinning connection
  • Fused to protect low voltage system transformers
  • 120 VAC igniter output
  • 120 VAC humidifier output
  • 120 VAC electronic air cleaner output
  • 120 VAC 2-speed PSC circulator output
  • 5 amp fuse protection
  • Furnace status LED
  • Heat fan off delay (dipswitch selectable)
  • 1.5 amp valve relay
  • 6 amp igniter relay
  • 2.2 amp full load - 3.5 amp locked rotor inducer relay
  • 14.5 amp full load - 25 amp locked rotor circulator relay
  • 1 micro-amp DC minimum current
  • 0.10 micro-amp DC max current
  • 100 mega-ohm leakage resistance
  • Maximum timing specification
  • 0.8 sec flame establishing
  • Flash code diagnostics The 50A55-743 is an automatic gas interrupted ignition control that employs a microprocessor to continually monitor, analyze, and control the proper operation of the gas burner, inducer, and fan. signals interpreted during continual surveillance of the thermostat and flame sensing element initiate automatic ignition of the burner, sensing of the flame, and system shutoff during normal operation. these controls incorporate system fault analysis for quick gas flow shutoff , coupled with automatic ignition retry upon sensing a fault correction. it is designed as a replacement for the following controls.Sid Harvey Item #:50A55-743: Replaces Part #:'s : 50A55-289,

    white rodgers 50a55-743

Item#:
50A55-743
Manufacturer Item:
50A55-743
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
The 50A55-3797 is an automatic gas interrupted ignition control that employs a microprocessor to continually monitor, analyze, and control the proper operation of the gas burner, inducer, and fan. signals interpreted during continual surveillance of the thermostat and flame sensing element initiate automatic ignition of the burner, sensing of the flame, and system shutoff during normal operation. these controls incorporate system fault analysis for quick gas flow shutoff , coupled with automatic ignition retry upon sensing a fault correction. it is designed as a replacement for the following controls.
  • Fused to protect low VAC age system transformers
  • 120 VAC igniter output
  • 120 VAC humidifier output
  • 120 VAC electronic air cleaner output
  • 120 VAC 2-speed PSC circulator output
  • 5 amp fuse protection
  • Furnace status LED
  • Heat fan off delay (dipswitch selectable)
  • 1.5 amp valve relay
  • 6 amp igniter relay
  • 2.2 amp full load - 3.5 amp locked rotor inducer relay
  • 14.5 amp full load - 25 amp locked rotor circulator relay
  • 1 micro-amp DC minimum current
  • 0.1 micro-amp DC max current
  • 100 mega-ohm leakage resistance
  • Maximum timing specification
  • 0.8 sec flame establishing
  • 2 sec flame failure response time
  • Flash code diagnostics
,


White Rodgers 5059-134

Item#:
50A55-3797
Manufacturer Item:
50A55-3797
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 50M56X-843 Universal Single Stage HSI Integrated Furnace Control For PSC & ECMx Blower Motor

White Rodgers 49M11-843

Item#:
50M56X-843
Manufacturer Item:
50M56X-843
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
The 50A65-5165 is an automatic gas interrupted ignition control that employs a microprocessor to continually monitor, analyze, and control the proper operation of the gas burner, inducer, and fan. signals interpreted during continual surveillance of the thermostat and flame sensing element initiate automatic ignition of the burner, sensing of the flame, and system shutoff during normal operation. these controls incorporates system fault analysis for quick gas flow shutoff , coupled with automatic ignition retry upon sensing a fault correction. it is designed as a replacement for the following controls.
  • Twinning connection
  • Fused to protect low VAC age system transformers
  • 1.5 amp valve relay
  • 6 amp igniter relay
  • 2.2 amp full load - 3.5 amp locked rotor inducer relay
  • 14.5 amp full load - 25 amp locked rotor circulator relay
  • 1 micro-amp DC minimum current
  • 0.10 micro-amp DC max current
  • 100 mega-ohm leakage resistance
  • Maximum timing specification
  • 0.8 sec flame establishing
  • 2 sec flame failure response time
  • 77 deg F electrical rating
  • Flash code diagnostics, controls gas valve, igniter, blower, inducer, 120 VAC humidifier and air cleaner
Sid Harvey Item #:50A65-5165: Replaces Part #:'s : CNT05165 | CNT5165 |,


White Rodgers 50A55-3797

Item#:
50A65-5165
Manufacturer Item:
50A65-5165
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 49M11-843 Contactor Sureswitch Multi-Volt 40 AMP

White Rodgers 1F76U-22WFB

Item#:
49M11-843
Manufacturer Item:
49M11-843
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 50D50U-843 Universal Intermittent Pilot All Spark 24V Ignition Module,

White Rodgers 21D64-5PK

Item#:
50D50U-843
Manufacturer Item:
50D50U-843
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 50E47-843 Silicon Carbide Universal Non-Integrated Hot Surface Ignition Control Kit, 18 - 30 VAC, 0.2 amp
  • Program keys for easy customization
  • Tri-color LED indicator for diagnostics
  • Direct and indirect flame sense
  • Replaces all White Rodgers Cooling Controls 50E47-xxx modules and virtually all competitive silicon carbide, non-integrated modules
  • 6 amp at 120 VAC, 60 Hz resistive igniter relay
  • Includes program keys, mounting hardware, double-sided foam back tape (for ease of installation), extensive cross-reference guide, color-coded timing label, pre-printed hanging carTon, instructions in english/instructions en espanol
  • 95% RH non-condensing humidity range
Sid Harvey Item #:50E47-843: Replaces Part #:'s : HS780-17NL-104A | HS780-17NL-106A | HS780-17NL-108A | HS780-17NL-304A | HS780-17NL-306A | HS780-17NL-308A | HS780-17NR-104A | HS780-17NR-106A | HS780-17NR-108A | HS780-17NR-304A | HS780-17NR-306A | HS780-17NR-308A | HS780-17NR-312A | HS780-17PL-106A | HS780-17PL-108A | HS780-17PL-304A | HS780-17PL-306A | HS780-17PL-308A | HS780-17PR-104A | HS780-17PR-108A | HS780-17PR-306A | HS780-34NL-106A | HS780-34NL-108A | HS780-34NL-304A | HS780-34NL-306A | HS780-34NL-308A | HS780-34NL-312A | HS780-34NR-104A | HS780-34NR-106A | HS780-34NR-304A | HS780-34NR-306A | HS780-34NR-308A | HS780-34NR-312A | HS780-34PL-104A | HS780-34PL-106A | HS780-34PL-108A | HS780-34PL-304A | HS780-34PL-306A | HS780-34PL-308A | HS780-34PR-106A | HS780-34PR-108A | HS780-34PR-304A | HS780-34PR-306A | HS780-34PR-308A |,

white rodgers 50e47-843

Item#:
50E47-843
Manufacturer Item:
50E47-843
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
Item#:
50E70-820
Item#:
50D50-842
White Rodgers Cooling Controls 50D50-843 Universal Intermittent Pilot Spark Ignition Module for Gas-Fired Non-Integrated Forced Air Furnaces, 25 VAC, 0.2 amp, 4.13" W x 4.13" H x 1-1/2" D
  • Color LED indicator for diagnostics
  • Includes program keys, double-sided foam back tape, color coded timing label, pre-printed hanging carTon
  • 1/4 and 3/16" quick connect terminals
  • Direct and indirect flame senseSid Harvey Item #:50D50-843: Replaces Part #:'s : CSA35A-617R | CSA35A-618R | CSA42A-600R | CSA42A-601R | CSA42A-602R | CSA42A-603R | CSA42A-604R | CSA43A-600R | CSA44A-600R | CSA45A-601R | CSA45A-602R | CSA46A-600R | CSA48A-600R | CSA49A-600R | CSA49A-605R | CSA51A-601R | CSA52A-600R,

    white rodgers 50d50-843

Item#:
50D50-843
Manufacturer Item:
50D50-843
Manufacturer:
WHITE-RODGERS DIV OF COPELAND