White Rodgers Cooling Controls 50M56-743 Hot Surface Igniter Nitride Integrated Furnace Control, 25 VAC, 0.45 amp, 50/60 Hz
    System diagnostic LED with fault recall
  • Multi speed circulator
  • 1 or 2-stage gas valve
  • Relay load ratings - 1.5 amp at 25 VAC 50/60 Hz 0.6 pico-F valve relay, 6 amp at 120 VAC 50/60 Hz (resistive) igniter relay, 2.2 amp full load, 3.5 amp locked rotor at 120 VAC inducer relay, 14.5 amp full load, 25 amp locked rotor at 120 VAC circulator relay
  • Flame current requirements - 1 micro-amp DC minimum current to insure flame detection, 0.10 micro-amp DC maximum current for non-detection, 100 mega-ohm maximum allowable leakage resistance
  • 0.8 sec flame establishing time, 2 sec flame failure response time

    White Rodgers 50M56-743

Item#:
50M56-743
Manufacturer Item:
50M56-743
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
Quick View
White Rodgers Cooling Controls 50A65-843 Universal Nitride Ignition Furnace Control, 25 The 50A55-843 universal silicon carbide integrated ignition module employs a microprocessor which continually monitors, analyzes and controls the proper operation of the gas burner, inducer and fan. This one module will replace most of the 50A5x-xxx integrated ignition carbide modules that have been manufactured by White-Rodgers for most OEM applications. The universal module includes an extensive cross-reference, additional jumper wires, additional wiring harness and a jumper for Trane applications. The module also has terminals for powering a humidifier and electronic air cleaner

White Rodgers 50A65-843

Item#:
50A65-843
Manufacturer Item:
50A65-843
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
Quick View
The 50A66-743 is an automatic gas interrupted ignition control that employs a microprocessor to continually monitor, analyze, and control the proper operation of the gas burner, inducer, and fan. signals interpreted during continual surveillance of the thermostat and flame sensing element initiate automatic ignition of the burner, sensing of the flame, and system shutoff during normal operation. these controls incorporate system fault analysis for quick gas flow shutoff , coupled with automatic ignition retry upon sensing a fault correction.
    3-fan speeds
  • Remote flame sensing
  • Humidifier and electronic air cleaner connections (optional)
  • 1.5 amp valve relay
  • 6 amp igniter relay
  • 2.2 amp full load - 3.5 amp locked rotor inducer relay
  • 14.5 amp full load - 25 amp locked rotor circulator relay
  • Diagnostic indicator flash codes, controls gas valve, igniter, blower, inducer, humidifier and air cleaner
Sid Harvey Item #:50A66-743: Replaces Part #:'s : 100925-01 | 100925-02 | 100925-03 | 10092501 | 10092502 | 10092503 |

White Rodgers 50A66-743

Item#:
50A66-743
Manufacturer Item:
50A66-743
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
Quick View
White Rodgers Cooling Controls 50A56-956 Replacement Integrated Furnace Control, 25 VAC , The 50A56-956 is an automatic gas interrupted ignition control that employs a microprocessor to continually monitor, analyze, and control the proper operation of the gas burner, inducer, and fan. signals interpreted during continual surveillance of the thermostat and flame sensing element initiate automatic ignition of the burner, sensing of the flame, and system shutoff during normal operation. these controls incorporate system fault analysis for quick gas flow shutoff , coupled with automatic ignition retry upon sensing a fault correction.

White Rodgers 50A56-956

Item#:
50A56-956
Manufacturer Item:
50A56-956
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
Quick View
White Rodgers Cooling Controls 50D50U-843 Universal Intermittent Pilot All Spark 24V Ignition Module,White Rodgers 50D50U-843

White Rodgers 50D50U-843

Item#:
50D50U-843
Manufacturer Item:
50D50U-843
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
Quick View
White Rodgers Cooling Controls 50E70-820 HSI Integrated Furnace Control, 18 - 30 VAC, 60 Hz
  • 1-stage applications
  • 120 volt HSI ignition
  • Adapter board and harness included
  • For packaged units
  • Flame current test pins
  • Red and green status LEDs
  • Standoffs/adapter board mounting
  • 0.8 sec flame establishing time, 2 sec flame failure response time at 60 Hz
  • Flame current requirements - minimum current to insure flame detection: 1 micro-amp DC, maximum current for non-detection: 0.1 micro-amp DC, maximum allowable leakage resistance: 100 mega-ohm,

    White Rodgers 50E70-820

Item#:
50E70-820
Manufacturer Item:
50E70-820
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
Quick View
White Rodgers Cooling Controls SureSwitch 49M11-843

White Rodgers 49M11-843

Item#:
49M11-843
Manufacturer Item:
49M11-843
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
Quick View
White Rodgers Cooling Controls 50M56U-751 1-Stage HSI Integrated Furnace Control Kit for

White Rodgers 50M56U-751

Item#:
50M56U-751
Manufacturer Item:
50M56U-751
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
Quick View
White Rodgers Cooling Controls 50C51-707 2-Stage HSI Integrated Furnace Control 24 VAC

White Rodgers 50C51-707

Item#:
50C51-707
Manufacturer Item:
50C51-707
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
Quick View
White Rodgers Cooling Controls SureSwitch 49P11-843 1.5-Pole Relay, 24 VAC at 50/60 Hz, 40,

White Rodgers 49P11-843

Item#:
49P11-843
Manufacturer Item:
49P11-843
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
Quick View
White Rodgers Cooling Controls 5059-134 Pilot Relite Control, 24 VAC, 0.03 amp
    Generates spark pulse until flame is sensed through spark electrode
  • Begins sparking immediately if flame extinguishes
  • Rugged solid state module design
  • Spike terminal high voltage and 1/4" spade terminals connection
Replaces Part #:'s : CNT01011

White Rodgers 5059-134

Item#:
5059-134
Manufacturer Item:
5059-134
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
Quick View
White Rodgers Cooling Controls 57T01-843 Blower Time Delay Relay, 24 VAC
    Allows residual cooled air to be blown into the controlled space, increasing the efficiency of the system in cooling
  • Depending on electrical hook-up in a heat pump system, delay of blower shut-off could also occur in heating
  • Contact rating power pole: 7 amp full load, 36 amp locked rotor, 15 amp resistive, 3/4 HP at 208/240/277 VAC

    White Rodgers 57T01-843

Item#:
57T01-843
Manufacturer Item:
57T01-843
Manufacturer:
WHITE-RODGERS DIV OF COPELAND