Danfoss MTZ36-4VI Hermetic Refrigeration Compressor 36000 BTU 460 VAC 3 HP,
,

Item#:
MTZ36-4VI
Manufacturer Item:
MTZ36-4VI
Manufacturer:
DANFOSS LLC(HVAC/R)
Danfoss MTZ64-3VI Hermetic Refrigeration Compressor
  • 5-1/2 HP 230 VAC
    • POE Oil
      • POE, R404A, R407C, R134A
        • 1-3/4" RL - 7/8" x 1-1/4" RL - 3/4",

Item#:
MTZ64-3VI
Manufacturer Item:
MTZ64HM3AVE
Manufacturer:
DANFOSS LLC(HVAC/R)
Danfoss 195B0586 Refrigeration Compressor R134A 115/1 Low Temperature,
,

Item#:
195B0586
Manufacturer Item:
195B0586
Manufacturer:
DANFOSS LLC(HVAC/R)
Danfoss Hermetic Refrigeration Compressor
  • 2 HP 208/230 VAC R134A, R404A, R407C, R407F, R507A
Replacement Parts Below
8153011 Adaptor
8156009 Gasket Gasket set, 1", 1-1/4", 1-3/4", OSG gaskets black and white
8156131 Gasket 1-1/4"
120Z0575 Acoustic hood for one-cylinder compressor
8153007 Solder sleeve, P06 (1" rotolock, 1/2" ODF)
8156001 Mounting Kit
7750009 Discharge thermostat kit
8156130 Gasket 1"
7703005 Valve set, V09 (1-1/4"~5/8"), V06 (1"~1/2"), Service kit

Item#:
MTZ22-1VI
Manufacturer Item:
MTZ22JC1BVE
Manufacturer:
DANFOSS LLC(HVAC/R)
Danfoss 013G8015 Nickel-Plated Brass Straight Thermostatic Radiator Valve Body, 1/2", FPT x MPT Union Tailpiece
  • Valve bodies are designed to meet the demands of the residential, commercial and industrial sectors
  • Thermostatic radiator valves regulate the flow of hot water or low pressure steam through free-standing radiators, baseboards or convectors in hot water and 2-pipe steam systems
  • Valves are fitted with a packing gland assembly that is replaceable while the system is in operation
  • EPDM rubber valve disc provides a seal against the valve seat at differential pressures of up to 15 psig in hot water heating systems, while 15 psig for low pressure steam systems
  • Manual plastic cap supplied to protect the valve pusHPin and provide manual control of the valve during installation
  • Valves remain normally open with no operator mounted
  • Brass bonnet, spindle, nickel-plated brass tailpiece, union nut, EPDM disc, packing O-ring, stainless steel spring
Sid Harvey Item #:013G8015: Replaces Part #:'s : 5836,
,

Item#:
013G8015
Manufacturer Item:
013G8015
Manufacturer:
DANFOSS LLC(HVAC/R)
Danfoss 023Z8261 Liquid Line Filter Drier 1/4" OD
  • Applications:
  • Traditional refrigeration
  • Air conditioning units
  • Transport refrigeration

  • Item#:
    023Z8261
    Manufacturer Item:
    DCL-1.52/CAPSV
    Manufacturer:
    DANFOSS LLC(HVAC/R)
    Danfoss 060-5233 Low Pressure Control 36" Cap W/1/4" Flare Nut Auto Reset
    ,

    Item#:
    060-5233
    Manufacturer Item:
    KPU1
    Manufacturer:
    DANFOSS LLC(HVAC/R)
    Flow Rate
  • Atomizing nozzles are available in a wide range of flow rates, all but eliminating the need for specially calibrated nozzles. Between 1.00 GPH and 2.00 GPH, for example, seven different flow rates are available. Generally, with hot water and warm air heat, the smallest firing rate that will adequately heat the house on the coldest day is the proper size to use and the most economical. Short on-cycles result in low efficiency. Another guideline is to select the flow rate that provides a reasonable stack temperature regardless of the connected load. (According to the New England Fuel Institute, aim for a stack temperature of 400°F or lower on matched packaged units or 500°F or lower on conversion burners.) If the boiler or furnace is undersized for the load, it may be necessary to fire for the load and ignore the efficiency
    Spray Angle
  • Spray angles are available from 30° through 90° in most nozzle sizes to meet the requirements of a wide variety of burner air patterns and combustion chambers. Usually it is desirable to fit the spray angle to the air pattern of the burner. In todays flame retention burner, it is possible to fire more than one spray angle with good results. Generally, round or square combustion chambers should be fired with 70° to 90° nozzles. Long, narrow chambers usually require 30° to 60° spray angles.
  • Burner Air Patterns
  • Burner air patterns are much like nozzle spray patterns in that they fall into the same general classifications, either hollow or solid. As you would expect, a burner with a hollow air pattern generally requires a hollow cone fuel nozzle. A burner with a solid air pattern will give highest efficiency with a solid cone nozzle, but the flame will probably be longer.

  • Item#:
    1.00-60AS
    Manufacturer:
    DANFOSS LLC(HVAC/R)
    Flow Rate
  • Atomizing nozzles are available in a wide range of flow rates, all but eliminating the need for specially calibrated nozzles. Between 1.00 GPH and 2.00 GPH, for example, seven different flow rates are available. Generally, with hot water and warm air heat, the smallest firing rate that will adequately heat the house on the coldest day is the proper size to use and the most economical. Short on-cycles result in low efficiency. Another guideline is to select the flow rate that provides a reasonable stack temperature regardless of the connected load. (According to the New England Fuel Institute, aim for a stack temperature of 400°F or lower on matched packaged units or 500°F or lower on conversion burners.) If the boiler or furnace is undersized for the load, it may be necessary to fire for the load and ignore the efficiency
    Spray Angle
  • Spray angles are available from 30° through 90° in most nozzle sizes to meet the requirements of a wide variety of burner air patterns and combustion chambers. Usually it is desirable to fit the spray angle to the air pattern of the burner. In todays flame retention burner, it is possible to fire more than one spray angle with good results. Generally, round or square combustion chambers should be fired with 70° to 90° nozzles. Long, narrow chambers usually require 30° to 60° spray angles.
  • Burner Air Patterns
  • Burner air patterns are much like nozzle spray patterns in that they fall into the same general classifications, either hollow or solid. As you would expect, a burner with a hollow air pattern generally requires a hollow cone fuel nozzle. A burner with a solid air pattern will give highest efficiency with a solid cone nozzle, but the flame will probably be longer.

  • Item#:
    .65-70AS
    Manufacturer Item:
    030F7514
    Manufacturer:
    DANFOSS LLC(HVAC/R)
    Danfoss 060B017066 Oil Pressure Control 4-65 lb 45 Second Time Delay,
    ,

    Item#:
    060B017066
    Manufacturer Item:
    060B017066
    Manufacturer:
    DANFOSS LLC(HVAC/R)
    Danfoss HCZC0200UWF300N Air Cooled Condensing Unit, 2 hp, 14286 BTU/hr at 20 deg F, 22434 BTU/hr at 45 deg F, 230 VAC, R-404A, R-134A, R-507, R-407C
    • Includes: electrical box, receiver, dual pressure control, fan cycling control, dual fan units larger than 3 hp use KPU fan cycling control, filter drier, sight glass, solenoid valve with coil
    • Condenser designed for dependable performance in the toughest of high ambient conditions
    • Easy access service valves on all units
    • Universal high/medium/low range in R-404A fractional units
    • Compact design
    • 100% Factory tested
    • Quiet, efficient hermetic compressors, factory mounted and factory wired
    • Base mounted service valves with access port
    • Durable 14 ga painted steel base plate
    • Metal fan shroud and guard
    • Self-regulating PTC crank case heater on 1-1/2 hp and above
    • Lifting slots for easy and safe handling
    • Versions available for indoor and outdoor applications
    • Compressor sight glass on 1-1/2 hp and above
    • Receiver with liquid shut-off, and fusible plug standard on all units
    • Single fan
    • MTZ22 hermetic compressor
    • Complies with California standards
    • Medium back pressure
    Item#:
    HCZC0200UWF300N
    Manufacturer Item:
    114N6404
    Manufacturer:
    DANFOSS LLC(HVAC/R)
    Item#:
    LJZM0200UWH000Q
    Manufacturer Item:
    114N3480
    Manufacturer:
    DANFOSS LLC(HVAC/R)