Tjernlund DJ-3 In-line Induced Draft Blower for Smokepipe and Aids Proper Exhaust of Combustion Gas, 115 VAC , 1/70 HP, 1550 RPM
- Thermal protected
- Aluminized steel blower wheel
Item#:
106
Manufacturer Item:
DJ-3
Manufacturer:
TJERNLUND PRODUCTS INC
Tjernlund DB-2-6 Galvanized Steel Housing Inline Duct Booster Fan
- Drip proof - non ventilated thermal protection
- The DB-2 duct booster is designed to increase the flow of heated air in warm air heating systems or cooled air in central air conditioning systems
- The duct booster can be mounted on round or flat ducts
- 120 VAC
- 0.51 AMP
- 200 CFM
- 1550 RPM
Item#:
104-11
Manufacturer Item:
DB-2
Manufacturer:
TJERNLUND PRODUCTS INC
Tjernlund PS1505 Fan Prover has been designed to monitor the pressure within the fan housing only. A motor or wheel failure will decrease housing pressure and deactivate the pressure switch, thus preventing combustion.
- Simple installation
- Mounting hardware furnished
- Fixed setpoints
- Voltage - 125 VA pilot duty at 24 VAC, 300 VA pilot duty at 115 - 277 VAC, 15 amp non-inductive to 277 VAC
- Electric switch: SPST, normally open snap acting contacts
- Electric connectors #6-32 screw terminals with cup washer
- Control setpoint non-adjustable
- Operating pressure, on increasing vacuum pressure rise, 0.05 plus or minus 0.02 Inch WC with diaphragm in vertical position
- 1/2 psi maximum pressure
- -400 to 1900 deg F Operating temperature
- Diaphragm vertical mounting position
- 5-1/2 Inch across mounting bracket
Tjernlund 106-3 In-Line Draft Inducer 14" 14-3/4" W x 17" H x 10" D,
Item#:
106-3
Manufacturer Item:
IL
Manufacturer:
TJERNLUND PRODUCTS INC
Tjernlund D-3 Aluminized Steel Housing Inline Draft Inducer, 115 VAC, 0.96 amp, 1550 RPM, 1/20 HP
- Venturi action starts air moving up the stack instantly and keeps it moving smoothly
- In-line inducers are built for long-lasting, trouble-free service
- Vari-draft control permits adjustment to individual job requirements
- Vents/chimneys utilizing in-line draft inducers must be vertically terminated above the roof line
- Solves venting problems: Undersized chimneys, negative pressures, long horizontal vent connectors, down drafts, cold equipment starts, restrictive heat exchangers/combustion chambers
- 1 year warranty Tjernlund D-3 Aluminized Steel Housing Inline Draft Inducer, 115 VAC, 0.96 amp, 1550 RPM, 1/20 HP
Item#:
106-1
Manufacturer Item:
D-3
Manufacturer:
TJERNLUND PRODUCTS INC
Tjernlund I Inline Draft Inducer, 115 VAC , 1/4 HP, 1725 RPM
Item#:
106-2
Manufacturer Item:
I
Manufacturer:
TJERNLUND PRODUCTS INC
Tjernlund Specially designed to terminate Tjernlund Side Wall Vent Systems. They are also an approved method of terminating many horizontally vented appliances. Vent hoods feature heavy duty, corrosion resistant aluminum construction. Models VH1-3, 4 and 6 also have an additional heat shield for built in clearances from combustibles. Building exteriors are kept clean while the aesthetics of the structure remain undisturbed. All mounting hardware is included.
- 8" square rough-in
- Mounting hardware
Item#:
106-20
Manufacturer Item:
VH1-4
Manufacturer:
TJERNLUND PRODUCTS INC
Tjernlund Specially designed to terminate Tjernlund Side Wall Vent Systems. They are also an approved method of terminating many horizontally vented appliances. Vent hoods feature heavy duty, corrosion resistant aluminum construction. Models VH1-3, 4 and 6 also have an additional heat shield for built in clearances from combustibles. Building exteriors are kept clean while the aesthetics of the structure remain undisturbed. All mounting hardware is included.
- 9" rough-in diameter
- Mounting hardware
Item#:
106-21
Manufacturer Item:
VH1-6
Manufacturer:
TJERNLUND PRODUCTS INC
Tjernlund The SideShot models SS1 and SS2 SideWall Vent Systems include the UC1 Universal Control for increased safety, performance and reliability. Designed for oil fired heating equipment or a deluxe gas vent system. Patented vent termination propels flue gases at high velocities away from the building exterior, a necessity when venting oil fired equipment. Both models can be installed with zero clearance to combustible materials and have stainless steel construction in critical areas. Factory wired safety and operating controls allow simple interlock with any burner. The new model SS2 features a self-cleaning stainless steel, backward inclined impeller and sealed ball bearing motor for virtually maintenance free installations. Ultra-fine draft adjustment and slide-out access to all internal components. Easy multiple appliance interlocks with our MAC Series multiple appliance controls.
- Use to side wall vent non-condensing oil fired boilers, water heaters and furnaces that otherwise would require a conventional roof top terminated chimney
- Built-in interlock control with redundant high limit safety switch interfaces easily with thermostat, aquastat or primary controls
- Adjustable pre and post purge timing and easy fault code retrieval
- Stainless steel construction in all critical components including outdoor terminus
- Patented design jets flue gases away from the outside wall to eliminate potential staining of siding
Item#:
106-10
Manufacturer Item:
SS1
Manufacturer:
TJERNLUND PRODUCTS INC
Tjernlund 950-0800 Head Cooling Fan Motor 460 VAC
Tjernlund 950-0640 High Limit Switch SS-1,
Tjernlund 950-0640
Tjernlund 950-0640
Item#:
950-0640
Manufacturer Item:
950-0640
Manufacturer:
TJERNLUND PRODUCTS INC
Tjernlund 950-0650 Fan Prover Kit SS-1,
Tjernlund 950-0650
Tjernlund 950-0650